Using FIB Grooving to Prepare Top-down-Nanoprobed Sample for Site-Specific Cross-Sectional Nanoprobing Analysis

Abstract Cross-sectional analysis plays a crucial role in failure analysis for the identification of root causes associated with implants or junction profiles. Traditionally, this step involves junction staining. Recently, Electron Beam Induced Current (EBIC) analysis has emerged as a valuable alternative, offering the key advantage of visualizing various implantations and junction profiles through non-chemical means. This paper presents an innovative sample preparation technique for cross-sectional EBIC analysis, incorporating an additional step of FIB (Focused Ion Beam) grooving at the target site before cross-sectional polishing. Unlike conventional methods that involve laborious and time-consuming fine cross-sectional polishing, our approach enhances precision and efficiency. With the elimination of the need for extensive polishing, direct access to the target is achieved after rough polishing, thereby expediting the analytical process.

Authors

Institutions

Publication Details

Journal
Proceedings - International Symposium for Testing and Failure Analysis
Published
2024-10-23
DOI
https://doi.org/10.31399/asm.cp.istfa2024p0411
Primary Topic
Advanced Materials Characterization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using FIB Grooving to Prepare Top-down-Nanoprobed Sample for Site-Specific Cross-Sectional Nanoprobing Analysis

C.Q. Chen, Tianyuan Yu, S.L. Ting, P.K. Tan et al.
Proceedings - International Symposium for Testing and Failure Analysis
Advanced Materials Characterization Techniques
article

Using FIB Grooving to Prepare Top-down-Nanoprobed Sample for Site-Specific Cross-Sectional Nanoprobing Analysis

C.Q. Chen, Tianyuan Yu, S.L. Ting, P.K. Tan, P.T. Ng
article en

Abstract

Abstract Cross-sectional analysis plays a crucial role in failure analysis for the identification of root causes associated with implants or junction profiles. Traditionally, this step involves junction staining. Recently, Electron Beam Induced Current (EBIC) analysis has emerged as a valuable alternative, offering the key advantage of visualizing various implantations and junction profiles through non-chemical means. This paper presents an innovative sample preparation technique for cross-sectional EBIC analysis, incorporating an additional step of FIB (Focused Ion Beam) grooving at the target site before cross-sectional polishing. Unlike conventional methods that involve laborious and time-consuming fine cross-sectional polishing, our approach enhances precision and efficiency. With the elimination of the need for extensive polishing, direct access to the target is achieved after rough polishing, thereby expediting the analytical process.

Proceedings - International Symposium for Testing and Failure AnalysisVol. 84918
GlobalFoundries (Singapore) (SG)
Openalex Percentile: Top 83%
Advanced Materials Characterization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using FIB Grooving to Prepare Top-down-Nanoprobed Sample for Site-Specific Cross-Sectional Nanoprobing Analysis — C.Q. Chen, Tianyuan Yu, et al. · Proceedings - International Symposium for Testing and Failure Analysis (2024) | TGRS Research Map | TGRS