The Impact of TEM Analysis Temperature on Photoresist Profiles Using Cryo-FIB and Cryo-TEM

Abstract Photoresist (PR) profiles tend to have deformation and shrinkage with typical transmission electron microscopy (TEM) analysis method using a focused ion beam scanning electron microscope (FIB-SEM) and TEM. The elevated temperatures during sample preparation and TEM analysis are believed to contribute to these issues. This study evaluates the effectiveness of cryogenic workflow in mitigating PR profile shrinkage by employing cryo-focused ion beam (Cryo-FIB) and cryo-transmission electron microscopy (Cryo-TEM). Comparative experiments were conducted at room temperature and cryogenic conditions, demonstrating that full cryogenic workflow reduces the shrinkage of PR, bottom anti-reflective coating (BARC), and line critical dimension (CD). Our findings indicate that both the sample preparation and analysis temperatures influence PR profiles. This study highlights how the full cryogenic workflow significantly minimizes shrinkage, providing more accurate PR profile measurements.

Authors

Institutions

Publication Details

Journal
Proceedings - International Symposium for Testing and Failure Analysis
Published
2024-10-23
DOI
https://doi.org/10.31399/asm.cp.istfa2024p0221
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of TEM Analysis Temperature on Photoresist Profiles Using Cryo-FIB and Cryo-TEM

In Chang Choi, Ji Hye Hyun, Christopher H. Kang, Yanchao Dai
Proceedings - International Symposium for Testing and Failure Analysis
Integrated Circuits and Semiconductor Failure Analysis
article

The Impact of TEM Analysis Temperature on Photoresist Profiles Using Cryo-FIB and Cryo-TEM

In Chang Choi, Ji Hye Hyun, Christopher H. Kang, Yanchao Dai
article en

Abstract

Abstract Photoresist (PR) profiles tend to have deformation and shrinkage with typical transmission electron microscopy (TEM) analysis method using a focused ion beam scanning electron microscope (FIB-SEM) and TEM. The elevated temperatures during sample preparation and TEM analysis are believed to contribute to these issues. This study evaluates the effectiveness of cryogenic workflow in mitigating PR profile shrinkage by employing cryo-focused ion beam (Cryo-FIB) and cryo-transmission electron microscopy (Cryo-TEM). Comparative experiments were conducted at room temperature and cryogenic conditions, demonstrating that full cryogenic workflow reduces the shrinkage of PR, bottom anti-reflective coating (BARC), and line critical dimension (CD). Our findings indicate that both the sample preparation and analysis temperatures influence PR profiles. This study highlights how the full cryogenic workflow significantly minimizes shrinkage, providing more accurate PR profile measurements.

Proceedings - International Symposium for Testing and Failure AnalysisVol. 84918
Thermo Fisher Scientific (China) (CN)
Openalex Percentile: Top 84%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Impact of TEM Analysis Temperature on Photoresist Profiles Using Cryo-FIB and Cryo-TEM — In Chang Choi, Ji Hye Hyun, et al. · Proceedings - International Symposium for Testing and Failure Analysis (2024) | TGRS Research Map | TGRS