Proficiency test of SARS-CoV-2 Omicron variant detection in diagnostics samples by veterinary diagnostic laboratories

Abstract Veterinary diagnostic laboratories (VDLs) play a critical role in screening both human and animal samples for SARS-CoV-2. To evaluate the SARS-CoV-2 detection methods used by VDLs, a proficiency test was performed by the US Food and Drug Administration’s Veterinary Laboratory and Investigation and Response Network in collaboration with two other organizations. Thirty-two sets of 12 blind-coded samples were prepared by fortifying Molecular Transport Medium (MTM) or feline feces with SARS-CoV-2 Omicron variant or non-SARS-CoV-2 equine coronavirus RNA at various concentrations and shipped to 32 participants for blinded (unbiased) analysis. Results were analyzed according to the principles of International Organization for Standardization 16140-2:2016 using two approaches such as establishing the rate of detection (ROD) and the success rate by applying the analysis of binary outcome by logit approach. ROD provided the overall assessment of laboratories performance, whereas the novel logit approach provided an insight to more specific analysis based on the complexity of each sample. The ROD was 83% and 98% for MTM samples at 200 and 20000 genome copies per 100 µL, respectively. Fecal samples were classified as challenging exploratory, and results were not included in the assessment of performance but discussion purposes only. Fecal samples exhibited matrix interference impacting the performance. The ROD was 44% and 89% for fecal samples at 2000 and 20000 genome copies per 100 µL, respectively. The non-COVID coronavirus RNA, which was used to address the specificity, did not interfere with methods used. Establishing the success rate by evaluating the qualitative results (detected/not detected) applying a logit approach revealed that, out of thirty-two participants, twenty-eight had satisfactory results, one participant had unsatisfactory results, and three participants had questionable results for MTM samples. For fecal samples, three participants out of thirty-two did not meet the expectations at higher concentrations. Lower concentrations of fecal samples were excluded from this analysis. Again, the fecal samples were considered as challenge samples and the results were provided to assist participants in their continuous efforts to improve their performance and not to evaluate their performance.

Authors

Institutions

Publication Details

Journal
Accreditation and Quality Assurance
Published
2024-10-23
DOI
https://doi.org/10.1007/s00769-024-01622-w
Citations
2
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.78

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proficiency test of SARS-CoV-2 Omicron variant detection in diagnostics samples by veterinary diagnostic laboratories

Steffen Uhlig, Megan R. Miller, Karina Hettwer, Kirstin Frost et al.
2 citations
Accreditation and Quality Assurance
SARS-CoV-2 detection and testing
0.78
article

Proficiency test of SARS-CoV-2 Omicron variant detection in diagnostics samples by veterinary diagnostic laboratories

Steffen Uhlig, Megan R. Miller, Karina Hettwer, Kirstin Frost, Leyi Wang, Sarah M. Nemser, Neha Singh, Andriy Tkachenko, Matthew Kmet, Matthew C. Allender, Jodie Ulaszek, Ravinder Reddy
article en
2 citations

Abstract

Abstract Veterinary diagnostic laboratories (VDLs) play a critical role in screening both human and animal samples for SARS-CoV-2. To evaluate the SARS-CoV-2 detection methods used by VDLs, a proficiency test was performed by the US Food and Drug Administration’s Veterinary Laboratory and Investigation and Response Network in collaboration with two other organizations. Thirty-two sets of 12 blind-coded samples were prepared by fortifying Molecular Transport Medium (MTM) or feline feces with SARS-CoV-2 Omicron variant or non-SARS-CoV-2 equine coronavirus RNA at various concentrations and shipped to 32 participants for blinded (unbiased) analysis. Results were analyzed according to the principles of International Organization for Standardization 16140-2:2016 using two approaches such as establishing the rate of detection (ROD) and the success rate by applying the analysis of binary outcome by logit approach. ROD provided the overall assessment of laboratories performance, whereas the novel logit approach provided an insight to more specific analysis based on the complexity of each sample. The ROD was 83% and 98% for MTM samples at 200 and 20000 genome copies per 100 µL, respectively. Fecal samples were classified as challenging exploratory, and results were not included in the assessment of performance but discussion purposes only. Fecal samples exhibited matrix interference impacting the performance. The ROD was 44% and 89% for fecal samples at 2000 and 20000 genome copies per 100 µL, respectively. The non-COVID coronavirus RNA, which was used to address the specificity, did not interfere with methods used. Establishing the success rate by evaluating the qualitative results (detected/not detected) applying a logit approach revealed that, out of thirty-two participants, twenty-eight had satisfactory results, one participant had unsatisfactory results, and three participants had questionable results for MTM samples. For fecal samples, three participants out of thirty-two did not meet the expectations at higher concentrations. Lower concentrations of fecal samples were excluded from this analysis. Again, the fecal samples were considered as challenge samples and the results were provided to assist participants in their continuous efforts to improve their performance and not to evaluate their performance.

Accreditation and Quality AssuranceVol. 30(1)
Center for Food Safety and Applied Nutrition (US), Center for Veterinary Medicine (US), United States Food and Drug Administration (US), University of Illinois Urbana-Champaign (US), Illinois Institute of Technology (US), Chicago Zoological Society (US), Institute for Food Safety and Health (US)
U.S. Department of Agriculture, U.S. Geological Survey, University of Illinois at Urbana-Champaign, Animal and Plant Health Inspection Service
Partnerships for the goals
Openalex Percentile: Top 27%
SARS-CoV-2 detection and testing
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.