Heart Rate Estimation Considering Reconstructed Signal Features Based on Variational Mode Decomposition via Multiple-Input Multiple-Output Frequency Modulated Continuous Wave Radar

Accurate heart rate estimation using Doppler radar and Frequency Modulated Continuous Wave (FMCW) radar is highly valued for privacy protection and the ability to measure through clothing. Conventional methods struggle to isolate the heartbeat from respiration and body motion. This paper introduces a novel heart rate estimation method using Variational Mode Decomposition (VMD) via Multiple-Input Multiple-Output (MIMO) FMCW radar. The proposed method first estimates human positions within the radar's coverage, reducing noise by focusing on signals from these positions. The signal is then decomposed into multiple Intrinsic Mode Function (IMF) signals using VMD, and the heartbeat-specific IMF is extracted based on its center frequency. The heart rate signal is reconstructed using weighted addition of IMF signals for each radar cell, with cells defined by specific angles and distances within the coverage area. Peak detection is used to estimate heart rate from these reconstructed signals. To ensure accuracy, the method selects the heart rate estimate with the highest energy and periodicity for the first four time windows. From the fifth time window onward, it selects the estimate closest to the average of the previous four, minimizing extraneous variations. Experiments conducted with one and two subjects showed promising results. In case 1, with one subject, the method achieved a Mean Absolute Error (MAE) of 2.54 BPM and an exclusion rate of 0.94% using MIMO FMCW radar, compared to 4.72% with Doppler radar. In case 2, with two subjects, the method achieved an MAE of 2.28 BPM, confirming accurate simultaneous heart rate estimation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-10-23
DOI
https://doi.org/10.3390/s24216809
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart Rate Estimation Considering Reconstructed Signal Features Based on Variational Mode Decomposition via Multiple-Input Multiple-Output Frequency Modulated Continuous Wave Radar

Tomoaki Ohtsuki, Sara Nakatani, Mondher Bouazizi
2 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.37
article

Heart Rate Estimation Considering Reconstructed Signal Features Based on Variational Mode Decomposition via Multiple-Input Multiple-Output Frequency Modulated Continuous Wave Radar

Tomoaki Ohtsuki, Sara Nakatani, Mondher Bouazizi
article en
2 citations

Abstract

Accurate heart rate estimation using Doppler radar and Frequency Modulated Continuous Wave (FMCW) radar is highly valued for privacy protection and the ability to measure through clothing. Conventional methods struggle to isolate the heartbeat from respiration and body motion. This paper introduces a novel heart rate estimation method using Variational Mode Decomposition (VMD) via Multiple-Input Multiple-Output (MIMO) FMCW radar. The proposed method first estimates human positions within the radar's coverage, reducing noise by focusing on signals from these positions. The signal is then decomposed into multiple Intrinsic Mode Function (IMF) signals using VMD, and the heartbeat-specific IMF is extracted based on its center frequency. The heart rate signal is reconstructed using weighted addition of IMF signals for each radar cell, with cells defined by specific angles and distances within the coverage area. Peak detection is used to estimate heart rate from these reconstructed signals. To ensure accuracy, the method selects the heart rate estimate with the highest energy and periodicity for the first four time windows. From the fifth time window onward, it selects the estimate closest to the average of the previous four, minimizing extraneous variations. Experiments conducted with one and two subjects showed promising results. In case 1, with one subject, the method achieved a Mean Absolute Error (MAE) of 2.54 BPM and an exclusion rate of 0.94% using MIMO FMCW radar, compared to 4.72% with Doppler radar. In case 2, with two subjects, the method achieved an MAE of 2.28 BPM, confirming accurate simultaneous heart rate estimation.

SensorsVol. 24(21)
Keio University (JP)
Openalex Percentile: Top 43%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.