Safety and efficacy of using stapler device for wide cystic duct ligation in acute setting of laparoscopic cholecystectomy

This research explores the challenges posed by variations in cystic duct anatomy during laparoscopic cholecystectomy and the potential use of stapler devices to address such complexities. It aims to assess the safety and efficacy of stapler devices, particularly in cases involving short, and wide cystic duct. The study, conducted at King Abdulaziz Medical City in Riyadh, Saudi Arabia, between 2021 and 2023. The study design involved a retrospective cohort approach, and the sample size encompassed all cases meeting the inclusion criteria during the study period. Data was analyzed using SPSS program. The study involving 568 patients, with the predominant technique for ligation being clipping (89.3%). The primary indication for using the Endo GIA stapler was a wide cystic duct (6.2%). Analysis revealed a significant association between stapler device use and hypertension (p = 0.042), diabetes (p = 0.001), CKD (p = 0.011), and obstructive jaundice (p = 0.006). Multivariate regression demonstrated that older patients were 2.1 times more likely to use stapler devices (AOR = 2.125; p = 0.039), while those with obstructive jaundice had a 2.2 times higher likelihood (AOR = 2.168; p = 0.049). Throughout the years, metal clips have shown the best prognosis compared to any other method for securing the cystic duct during closure in laparoscopic cholecystectomy. However, to avoid incomplete sealing of wide, short, or inflamed ducts, other instruments have emerged as possible alternatives for such conditions. Use of Endo-GIA is a safe and effective method for patients with wide, short cystic duct. Selective usage of endo-GIA is considered cost effective and may add a positive impact in decreasing post operative biliary leak.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-23
DOI
https://doi.org/10.1038/s41598-024-75398-x
Citations
2
Primary Topic
Gastrointestinal disorders and treatments
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and efficacy of using stapler device for wide cystic duct ligation in acute setting of laparoscopic cholecystectomy

Ahad Alotaibi, Hatem J. Aljanfawe, Rifan Alyami, Bader Alhoumaily et al.
2 citations
Scientific Reports
Gastrointestinal disorders and treatments
1.15
article

Safety and efficacy of using stapler device for wide cystic duct ligation in acute setting of laparoscopic cholecystectomy

Ahad Alotaibi, Hatem J. Aljanfawe, Rifan Alyami, Bader Alhoumaily, Ibrahim Momen, Marya Algoblan
article en
2 citations

Abstract

This research explores the challenges posed by variations in cystic duct anatomy during laparoscopic cholecystectomy and the potential use of stapler devices to address such complexities. It aims to assess the safety and efficacy of stapler devices, particularly in cases involving short, and wide cystic duct. The study, conducted at King Abdulaziz Medical City in Riyadh, Saudi Arabia, between 2021 and 2023. The study design involved a retrospective cohort approach, and the sample size encompassed all cases meeting the inclusion criteria during the study period. Data was analyzed using SPSS program. The study involving 568 patients, with the predominant technique for ligation being clipping (89.3%). The primary indication for using the Endo GIA stapler was a wide cystic duct (6.2%). Analysis revealed a significant association between stapler device use and hypertension (p = 0.042), diabetes (p = 0.001), CKD (p = 0.011), and obstructive jaundice (p = 0.006). Multivariate regression demonstrated that older patients were 2.1 times more likely to use stapler devices (AOR = 2.125; p = 0.039), while those with obstructive jaundice had a 2.2 times higher likelihood (AOR = 2.168; p = 0.049). Throughout the years, metal clips have shown the best prognosis compared to any other method for securing the cystic duct during closure in laparoscopic cholecystectomy. However, to avoid incomplete sealing of wide, short, or inflamed ducts, other instruments have emerged as possible alternatives for such conditions. Use of Endo-GIA is a safe and effective method for patients with wide, short cystic duct. Selective usage of endo-GIA is considered cost effective and may add a positive impact in decreasing post operative biliary leak.

Scientific ReportsVol. 14(1)
Qassim University (SA), King Saud bin Abdulaziz University for Health Sciences (SA), King Abdulaziz Medical City (SA), Sion College (GB), King Abdullah International Medical Research Center (SA), National Guard Health Affairs (SA)
Openalex Percentile: Top 20%
Gastrointestinal disorders and treatments
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.