Protection of Hexagon Connections Using Reed Switches and Microprocessors with Majority Scheme and Functional Diagnostics

The necessity to improve the reliability of relay protection for connections at open switchgear with voltages of 110–750 kV is substantiated. It is shown that to achieve this, it is advisable to use the majority method, duplicating current transformers with reed switches. The properties of reed switches are described, and their advantages are highlighted in comparison with the use of other magnetic-sensitive elements. For connections of open switchgear configured in a hexagon scheme, a general backup protection is proposed, with one of the sets based on the principle of comparing the power sign on a microprocessor and current transformers, and the other two based on the use of Kirchhoff's law, a microprocessor, and reed switches, but without current transformers. The protection scheme is provided, and its behavior in various operating modes is examined. It is shown that such protection will be much more reliable and economical than previously proposed solutions.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/uralcon62137.2024.10718971
Primary Topic
VLSI and Analog Circuit Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protection of Hexagon Connections Using Reed Switches and Microprocessors with Majority Scheme and Functional Diagnostics

Dinara Amirbek
VLSI and Analog Circuit Testing
article

Protection of Hexagon Connections Using Reed Switches and Microprocessors with Majority Scheme and Functional Diagnostics

Dinara Amirbek
article en

Abstract

The necessity to improve the reliability of relay protection for connections at open switchgear with voltages of 110–750 kV is substantiated. It is shown that to achieve this, it is advisable to use the majority method, duplicating current transformers with reed switches. The properties of reed switches are described, and their advantages are highlighted in comparison with the use of other magnetic-sensitive elements. For connections of open switchgear configured in a hexagon scheme, a general backup protection is proposed, with one of the sets based on the principle of comparing the power sign on a microprocessor and current transformers, and the other two based on the use of Kirchhoff's law, a microprocessor, and reed switches, but without current transformers. The protection scheme is provided, and its behavior in various operating modes is examined. It is shown that such protection will be much more reliable and economical than previously proposed solutions.

Toraighyrov University (KZ)
Openalex Percentile: Top 81%
VLSI and Analog Circuit Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Protection of Hexagon Connections Using Reed Switches and Microprocessors with Majority Scheme and Functional Diagnostics — Dinara Amirbek · (2024) | TGRS Research Map | TGRS