Study of Parameters of a 6 kV Distributed Electrical Network in the Tarror Quarry

To ensure uninterrupted supply of electric energy to electric receivers, as well as for safe and reliable maintenance of electrical installations under operating voltage, it is necessary to know the insulation parameters according to which organizational and technical measures are being developed, the use of which allows to obtain positive effects both social and economic. This article discusses the developed methodology for determining insulation parameters in quarry distribution networks. Using the developed methodology, a study was conducted in the “Tarror” quarry, during which the dynamics of changes in the insulation resistance of the network phases relative to the ground was evaluated. Based on the results obtained, it was concluded that it is advisable to carry out such measurements at least a year in advance, which will make it possible to draw reasonable qualitative and quantitative conclusions about the influence of environmental parameters on the insulation resistance of phases of quarry distribution networks relative to the ground.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/uralcon62137.2024.10718946
Primary Topic
Geoscience and Mining Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Parameters of a 6 kV Distributed Electrical Network in the Tarror Quarry

Khurshedshoh Boboev, R. T. Abdullozoda, Olamafruz Sultonov
Geoscience and Mining Technology
article

Study of Parameters of a 6 kV Distributed Electrical Network in the Tarror Quarry

Khurshedshoh Boboev, R. T. Abdullozoda, Olamafruz Sultonov
article en

Abstract

To ensure uninterrupted supply of electric energy to electric receivers, as well as for safe and reliable maintenance of electrical installations under operating voltage, it is necessary to know the insulation parameters according to which organizational and technical measures are being developed, the use of which allows to obtain positive effects both social and economic. This article discusses the developed methodology for determining insulation parameters in quarry distribution networks. Using the developed methodology, a study was conducted in the “Tarror” quarry, during which the dynamics of changes in the insulation resistance of the network phases relative to the ground was evaluated. Based on the results obtained, it was concluded that it is advisable to carry out such measurements at least a year in advance, which will make it possible to draw reasonable qualitative and quantitative conclusions about the influence of environmental parameters on the insulation resistance of phases of quarry distribution networks relative to the ground.

South Ural State University (RU), Technological University of Tajikistan (TJ)
Openalex Percentile: Top 78%
Geoscience and Mining Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.