On-Body Wearable Antenna Performance Due to Different Medical Bandage Materials as the Substrates

The paper analyses the effect of different medical bandage materials that are commercially available in the medical industry as the antennas' substrate. Simulated magnitude of the reflection coefficient |S11| have shown noticeable deviation on the return loss and the resonant frequency due to different types of flexible substrate materials. Different types of medical bandage materials are characterized in terms of permittivity and loss tangent using open-ended coaxial probe method. Results have shown notable variation of approximately 12 % on the dielectric properties values due to the body proximity. The presented work may give an insight for the development of wearable telemedicine devices specifically in telemedicine system application.

Authors

Institutions

Publication Details

Published
2024-09-09
DOI
https://doi.org/10.1109/atnt61688.2024.10719130
Primary Topic
Antenna Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Body Wearable Antenna Performance Due to Different Medical Bandage Materials as the Substrates

Nabilah Ripin, Noor Asmawati Samsuri, Levy Olivia Nur, Bambang Setia Nugroho et al.
Antenna Design and Analysis
article

On-Body Wearable Antenna Performance Due to Different Medical Bandage Materials as the Substrates

Nabilah Ripin, Noor Asmawati Samsuri, Levy Olivia Nur, Bambang Setia Nugroho, Nur Sabrina Shukor
article en

Abstract

The paper analyses the effect of different medical bandage materials that are commercially available in the medical industry as the antennas' substrate. Simulated magnitude of the reflection coefficient |S11| have shown noticeable deviation on the return loss and the resonant frequency due to different types of flexible substrate materials. Different types of medical bandage materials are characterized in terms of permittivity and loss tangent using open-ended coaxial probe method. Results have shown notable variation of approximately 12 % on the dielectric properties values due to the body proximity. The presented work may give an insight for the development of wearable telemedicine devices specifically in telemedicine system application.

University of Technology Malaysia (MY), Telkom University (ID)
Openalex Percentile: Top 71%
Antenna Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-Body Wearable Antenna Performance Due to Different Medical Bandage Materials as the Substrates — Nabilah Ripin, Noor Asmawati Samsuri, et al. · (2024) | TGRS Research Map | TGRS