Simulation of the Active Corrector of Power Factor with Cascaded Two Loops Control for Electric Locomotive's Auxiliary Electric Drive

The object of study in the article is the auxiliary variable-frequency electric drive onboard of an AC electric locomotive, and more precisely, the structure and parameters of the control system of the active corrector of power factor (ACPF), which is part of the electric drive, as a unit that ensures electromagnetic compatibility of the electric drive with other equipment on board the electric locomotive and catenary and its energy efficiency. The topic of the article's research is the substantiation of the structure of the ACPF control system, the choice of types (transfer functions) of controllers and the calculation of their parameters. The research method chosen was the calculation of the transfer functions of the controllers of the cascaded loops control system, followed by computer simulation using the OrCAD software. The results of simulating a cascaded two loops control system of an ACPF with different types of controllers are presented and analytically compared. It is concluded that it is advisable to use a cascaded two loops control system, containing a voltage control loop and a current control loop. The best results show the simulation when using an aperiodic current controller (A-controller) and a proportional-integral voltage controller (PI-controller). The data obtained serve as the basis for further improvement of the operation of the ACPF by enhancing and optimizing the settings, structure and algorithms of the control system, which, with the selected hardware of power converter unit, will allow the ACPF to perform its functions with a high degree of reliability in an entire range of disturbing and control influences.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/uralcon62137.2024.10718875
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of the Active Corrector of Power Factor with Cascaded Two Loops Control for Electric Locomotive's Auxiliary Electric Drive

Mikhail Pustovetov, Anatoliy A. Lavrentyev
Electric Power Systems and Control
article

Simulation of the Active Corrector of Power Factor with Cascaded Two Loops Control for Electric Locomotive's Auxiliary Electric Drive

Mikhail Pustovetov, Anatoliy A. Lavrentyev
article en

Abstract

The object of study in the article is the auxiliary variable-frequency electric drive onboard of an AC electric locomotive, and more precisely, the structure and parameters of the control system of the active corrector of power factor (ACPF), which is part of the electric drive, as a unit that ensures electromagnetic compatibility of the electric drive with other equipment on board the electric locomotive and catenary and its energy efficiency. The topic of the article's research is the substantiation of the structure of the ACPF control system, the choice of types (transfer functions) of controllers and the calculation of their parameters. The research method chosen was the calculation of the transfer functions of the controllers of the cascaded loops control system, followed by computer simulation using the OrCAD software. The results of simulating a cascaded two loops control system of an ACPF with different types of controllers are presented and analytically compared. It is concluded that it is advisable to use a cascaded two loops control system, containing a voltage control loop and a current control loop. The best results show the simulation when using an aperiodic current controller (A-controller) and a proportional-integral voltage controller (PI-controller). The data obtained serve as the basis for further improvement of the operation of the ACPF by enhancing and optimizing the settings, structure and algorithms of the control system, which, with the selected hardware of power converter unit, will allow the ACPF to perform its functions with a high degree of reliability in an entire range of disturbing and control influences.

Don State Technical University (RU)
Affordable and clean energy
Openalex Percentile: Top 84%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of the Active Corrector of Power Factor with Cascaded Two Loops Control for Electric Locomotive's Auxiliary Electric Drive — Mikhail Pustovetov, Anatoliy A. Lavrentyev · (2024) | TGRS Research Map | TGRS