A fully integrated Hall Sensor Analog Front End with Analog closed loop self-calibration

This paper presents a fully integrated Hall sensor Analog Front End with an analog, closed loop, selfcalibration circuit, able to detect current values in the range of $\pm 120 \mathrm{~A}$ with a power supply voltage of 5 V. This calibration is performed using an integrated coil where a reference current flows. The proposed system can separate and extract the magnetic field generated by the reference current, compensating the sensitivity variation of the Hall sensors in temperature and mechanical stress, using an analog closed loop. Thanks to this fully integrated analog technique, experiments on fabricated chips have reported very low sensitivity drifts, with measured values of $100 \mathrm{ppm} /{ }^{\circ} \mathrm{C}$ and $\pm 0.3 \%$ variations over temperature and mechanical stress, respectively.

Authors

Institutions

Publication Details

Published
2024-09-09
DOI
https://doi.org/10.1109/esserc62670.2024.10719411
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fully integrated Hall Sensor Analog Front End with Analog closed loop self-calibration

Paolo Angelini, Francesco Borgioli, Dario Paci, Roberto Pio Baorda et al.
Magnetic Field Sensors Techniques
article

A fully integrated Hall Sensor Analog Front End with Analog closed loop self-calibration

Paolo Angelini, Francesco Borgioli, Dario Paci, Roberto Pio Baorda, Lorenzo Ercolini, Danilo Karim Kaddouri
article en

Abstract

This paper presents a fully integrated Hall sensor Analog Front End with an analog, closed loop, selfcalibration circuit, able to detect current values in the range of $\pm 120 \mathrm{~A}$ with a power supply voltage of 5 V. This calibration is performed using an integrated coil where a reference current flows. The proposed system can separate and extract the magnetic field generated by the reference current, compensating the sensitivity variation of the Hall sensors in temperature and mechanical stress, using an analog closed loop. Thanks to this fully integrated analog technique, experiments on fabricated chips have reported very low sensitivity drifts, with measured values of $100 \mathrm{ppm} /{ }^{\circ} \mathrm{C}$ and $\pm 0.3 \%$ variations over temperature and mechanical stress, respectively.

STMicroelectronics (Italy) (IT)
Affordable and clean energy
Openalex Percentile: Top 84%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.