Magneto-Active Metamaterials for 1.5T MRI: An Intelligent Approach to Boost the Signal-to-Noise Ratio of a Scan

Magnetic metamaterials can improve the performance of conventional MRI systems by boosting the magnetic fields in the region-of-interest under scan. However, these reported metamaterials amplify the electromagnetic fields during both RF transmission and reception during MRI scans. The amplification of RF fields by metamaterials during the transmission phase of MRI could lead to potential hazards for patients such as tissue heating, high specific absorption rate, etc. Thus, a magneto-active metamaterial is proposed for the 1.5T MRI that can selectively boost the received signals from the patient's body without affecting the transmitted signals during a scan. The magneto-active metamaterial could provide an intelligent way to enhance the MRI scanned images (boosts the SNR by 2.5 times), keeping patients’ safety in mind by minimizing potential scan threats.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.1109/nusod62083.2024.10723549
Citations
1
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magneto-Active Metamaterials for 1.5T MRI: An Intelligent Approach to Boost the Signal-to-Noise Ratio of a Scan

Debabrata Sikdar, S. Kanagaraj, Jegyasu Gupta, Rajesh V. Nair et al.
1 citations
Microwave Imaging and Scattering Analysis
0.18
article

Magneto-Active Metamaterials for 1.5T MRI: An Intelligent Approach to Boost the Signal-to-Noise Ratio of a Scan

Debabrata Sikdar, S. Kanagaraj, Jegyasu Gupta, Rajesh V. Nair, Ratnajit Bhattacharjee
article en
1 citations

Abstract

Magnetic metamaterials can improve the performance of conventional MRI systems by boosting the magnetic fields in the region-of-interest under scan. However, these reported metamaterials amplify the electromagnetic fields during both RF transmission and reception during MRI scans. The amplification of RF fields by metamaterials during the transmission phase of MRI could lead to potential hazards for patients such as tissue heating, high specific absorption rate, etc. Thus, a magneto-active metamaterial is proposed for the 1.5T MRI that can selectively boost the received signals from the patient's body without affecting the transmitted signals during a scan. The magneto-active metamaterial could provide an intelligent way to enhance the MRI scanned images (boosts the SNR by 2.5 times), keeping patients’ safety in mind by minimizing potential scan threats.

Indian Institute of Technology Guwahati (IN), Piramal (India) (IN)
Affordable and clean energy
Openalex Percentile: Top 51%
Microwave Imaging and Scattering Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.