Experience in Installing an Active High Harmonics Filter to Improve the Functioning of Specialized Medical Equipment

The introduction of digital technologies into energy systems and the intellectualization of energy networks force us to pay increasing attention to the issues of power quality control. Due to the rapid technological development of electrical equipment, there is a need to find new approaches to solving problems of electromagnetic compatibility. This article discusses the main aspects related to the impact of power quality violations on the operation of electrical equipment, including specialized equipment for medical institutions. For medical institutions, despite the importance of complying with power quality indicators, there are no special requirements for their control. However, violations of power quality parameters lead to a decrease in the accuracy of displaying diagnostic results, which leads to distortions in the study and the occurrence of errors, which in some cases can be fatal. The State Autonomous Healthcare Institution “Interregional Clinical Diagnostic Center” of the city of Kazan was considered as the object of the study. As a result of a study of the dynamics of power quality indicators at particularly critical facilities of the Interregional Clinical Diagnostic Center, a deviation of the total harmonic component coefficient of currents THDi of up to 48% was revealed. To combat this violation, an active higher harmonic filter was selected and installed, which is a universal means of protection and can simultaneously perform several functions: reducing the level of higher harmonic components, power factor correction, reducing power losses, reducing flicker, etc. Installing an active harmonic filter reduced THDi to 2.5%, which is within the existing international standards.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/uralcon62137.2024.10718955
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experience in Installing an Active High Harmonics Filter to Improve the Functioning of Specialized Medical Equipment

Olga I. Semenova, Р. Н. Хайруллин, Alina Denisova
Quality and Safety in Healthcare
article

Experience in Installing an Active High Harmonics Filter to Improve the Functioning of Specialized Medical Equipment

Olga I. Semenova, Р. Н. Хайруллин, Alina Denisova
article en

Abstract

The introduction of digital technologies into energy systems and the intellectualization of energy networks force us to pay increasing attention to the issues of power quality control. Due to the rapid technological development of electrical equipment, there is a need to find new approaches to solving problems of electromagnetic compatibility. This article discusses the main aspects related to the impact of power quality violations on the operation of electrical equipment, including specialized equipment for medical institutions. For medical institutions, despite the importance of complying with power quality indicators, there are no special requirements for their control. However, violations of power quality parameters lead to a decrease in the accuracy of displaying diagnostic results, which leads to distortions in the study and the occurrence of errors, which in some cases can be fatal. The State Autonomous Healthcare Institution “Interregional Clinical Diagnostic Center” of the city of Kazan was considered as the object of the study. As a result of a study of the dynamics of power quality indicators at particularly critical facilities of the Interregional Clinical Diagnostic Center, a deviation of the total harmonic component coefficient of currents THDi of up to 48% was revealed. To combat this violation, an active higher harmonic filter was selected and installed, which is a universal means of protection and can simultaneously perform several functions: reducing the level of higher harmonic components, power factor correction, reducing power losses, reducing flicker, etc. Installing an active harmonic filter reduced THDi to 2.5%, which is within the existing international standards.

Kazan State Power Engineering University (RU), State Autonomous Institution of Health Interregional Clinical Diagnostic Center (RU)
Affordable and clean energy
Openalex Percentile: Top 63%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experience in Installing an Active High Harmonics Filter to Improve the Functioning of Specialized Medical Equipment — Olga I. Semenova, Р. Н. Хайруллин, et al. · (2024) | TGRS Research Map | TGRS