A 206-Element, 250-µW/channel, 87-MHz Ultrasound Linear-Array Receiver with Monolithically Integrated Transducers for Photoacoustic Tomography

Photoacoustic tomography (PAT) is an imaging technique that offers the unique ability to achieve high spatial resolution at substantial depths within tissue. However, resolution and contrast in PAT are strongly dependent on the frequency and bandwidth of the ultrasound imager. High-bandwidth, high-frequency systems can be achieved by close integration of transducer and front-end electronics, which eliminates the need for a band-limiting matching network and reduces the effects of capacitive parasitics. We demonstrate the ability to collect ultrasound signals from photoacoustic phantoms up to $87-\mathrm{MHz}$ in a CMOS-based linear-array receiver, achieving an axial resolution of $15 \mu \mathrm{~m}$ and a lateral resolution of $30 \mu \mathrm{~m}$.

Authors

Institutions

Publication Details

Published
2024-09-09
DOI
https://doi.org/10.1109/esserc62670.2024.10719404
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 206-Element, 250-µW/channel, 87-MHz Ultrasound Linear-Array Receiver with Monolithically Integrated Transducers for Photoacoustic Tomography

Kenneth L. Shepard, Jeffrey Sherman, Volkan Arslan, Sinan Yilmaz et al.
1 citations
Photoacoustic and Ultrasonic Imaging
0.18
article

A 206-Element, 250-µW/channel, 87-MHz Ultrasound Linear-Array Receiver with Monolithically Integrated Transducers for Photoacoustic Tomography

Kenneth L. Shepard, Jeffrey Sherman, Volkan Arslan, Sinan Yilmaz, Ilke Uguz, Prashant Muthuraman, Jakub Jadwiszczak, Lei Li, Onuralp Karatum
article en
1 citations

Abstract

Photoacoustic tomography (PAT) is an imaging technique that offers the unique ability to achieve high spatial resolution at substantial depths within tissue. However, resolution and contrast in PAT are strongly dependent on the frequency and bandwidth of the ultrasound imager. High-bandwidth, high-frequency systems can be achieved by close integration of transducer and front-end electronics, which eliminates the need for a band-limiting matching network and reduces the effects of capacitive parasitics. We demonstrate the ability to collect ultrasound signals from photoacoustic phantoms up to $87-\mathrm{MHz}$ in a CMOS-based linear-array receiver, achieving an axial resolution of $15 \mu \mathrm{~m}$ and a lateral resolution of $30 \mu \mathrm{~m}$.

Rice University (US), Columbia University (US)
Affordable and clean energy
Openalex Percentile: Top 51%
Photoacoustic and Ultrasonic Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 206-Element, 250-µW/channel, 87-MHz Ultrasound Linear-Array Receiver with Monolithically Integrated Transducers for Photoacoustic Tomography — Kenneth L. Shepard, Jeffrey Sherman, et al. · (2024) | TGRS Research Map | TGRS