Secondary acute angle closure glaucoma after 25-gauge pars plana vitrectomy for a macular hole: a case report

This case presents a rare occurrence of secondary acute angle-closure glaucoma in a pseudophakic eye after 25-gauge minimally invasive pars plana vitrectomy and SF6 gas tamponade for macular hole. The cause was presumed to be posterior synechiae of the iris or relative pupillary block due to forward pushing of the intracapsular intraocular lens by vitreous gas. In cases where surgery is repeated without achieving macular hole closure, necessitating long-term face-down position, where vitreous gas is retained for an extended period, or when a large-diameter intraocular lens is implanted, secondary acute angle-closure glaucoma should be considered. This applies even when the 25-gauge pars plana vitrectomy is performed not for a highly invasive proliferative diabetic retinopathy but for macular hole repair, especially if the patient has a pseudophakic eye.

Authors

Institutions

Publication Details

Journal
Journal of Medical Case Reports
Published
2024-10-24
DOI
https://doi.org/10.1186/s13256-024-04859-8
Citations
2
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Secondary acute angle closure glaucoma after 25-gauge pars plana vitrectomy for a macular hole: a case report

Suguru Nakagawa, Shigefumi Takahashi, Kiyoshi Ishii
2 citations
Journal of Medical Case Reports
Retinal and Macular Surgery
0.81
article

Secondary acute angle closure glaucoma after 25-gauge pars plana vitrectomy for a macular hole: a case report

Suguru Nakagawa, Shigefumi Takahashi, Kiyoshi Ishii
article en
2 citations

Abstract

This case presents a rare occurrence of secondary acute angle-closure glaucoma in a pseudophakic eye after 25-gauge minimally invasive pars plana vitrectomy and SF6 gas tamponade for macular hole. The cause was presumed to be posterior synechiae of the iris or relative pupillary block due to forward pushing of the intracapsular intraocular lens by vitreous gas. In cases where surgery is repeated without achieving macular hole closure, necessitating long-term face-down position, where vitreous gas is retained for an extended period, or when a large-diameter intraocular lens is implanted, secondary acute angle-closure glaucoma should be considered. This applies even when the 25-gauge pars plana vitrectomy is performed not for a highly invasive proliferative diabetic retinopathy but for macular hole repair, especially if the patient has a pseudophakic eye.

Journal of Medical Case ReportsVol. 18(1)
Jichi Medical University (JP), Saitama Red Cross Hospital (JP), Jichi Medical University Saitama Medical Center (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 25%
Retinal and Macular Surgery
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.