A novel ventilation method: Experimental measurement and numerical simulation of vertical single-row inclined slit ventilation

• A novel ventilation method, Vertical Single-Row Inclined Slit Ventilation (VSISV), is proposed for delivering airflow to an indoor space through a series of spaced slits on a vertical main duct . • The VSISV effectively directs airflow downward from the ceiling, significantly reducing thermal stratification. • Compared to IJV, VSISV offers a more uniform and higher indoor temperature distribution , enhancing indoor thermal comfort without changing the airflow rate . Existing ventilation technologies often struggle to balance the limited airflow supply with the demands of indoor ventilation and air circulation in winter. This paper introduces a novel ventilation method, vertical single-row inclined slit ventilation (VSISV), which channels airflow through multiple inclined slits spaced at specific intervals along a vertical supply air duct. By ensuring continuity of the upstream and downstream slit jets, a continuous downward airflow is formed, enhancing both winter ventilation performance and indoor air circulation. The method was experimentally measured, with a focus on comparison to the IJV system. At the same airflow rate, it not only efficiently transports the supply air heat from the upper indoor area to the floor but also exhibits strong horizontal diffusion capability. The RNG turbulence model was selected for numerical simulation, focusing on indoor thermal comfort, air quality, and energy-saving potential. The results indicate that, at the same airflow rate, this method effectively maintains high indoor thermal comfort, directs airflow downward from the ceiling, reduces thermal stratification in the upper zone, achieves a more uniform and elevated indoor temperature, enhances indoor air quality, and demonstrates substantial energy-saving potential. This provides valuable insights for energy conservation, emission reduction, and the optimization in winter building ventilation systems.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2024-10-21
DOI
https://doi.org/10.1016/j.enbuild.2024.114944
Citations
5
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
1.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel ventilation method: Experimental measurement and numerical simulation of vertical single-row inclined slit ventilation

Chen Wang, Yin Liu, Ke Hu
5 citations
Energy and Buildings
Wind and Air Flow Studies
1.03
article

A novel ventilation method: Experimental measurement and numerical simulation of vertical single-row inclined slit ventilation

Chen Wang, Yin Liu, Ke Hu
article en
5 citations

Abstract

• A novel ventilation method, Vertical Single-Row Inclined Slit Ventilation (VSISV), is proposed for delivering airflow to an indoor space through a series of spaced slits on a vertical main duct . • The VSISV effectively directs airflow downward from the ceiling, significantly reducing thermal stratification. • Compared to IJV, VSISV offers a more uniform and higher indoor temperature distribution , enhancing indoor thermal comfort without changing the airflow rate . Existing ventilation technologies often struggle to balance the limited airflow supply with the demands of indoor ventilation and air circulation in winter. This paper introduces a novel ventilation method, vertical single-row inclined slit ventilation (VSISV), which channels airflow through multiple inclined slits spaced at specific intervals along a vertical supply air duct. By ensuring continuity of the upstream and downstream slit jets, a continuous downward airflow is formed, enhancing both winter ventilation performance and indoor air circulation. The method was experimentally measured, with a focus on comparison to the IJV system. At the same airflow rate, it not only efficiently transports the supply air heat from the upper indoor area to the floor but also exhibits strong horizontal diffusion capability. The RNG turbulence model was selected for numerical simulation, focusing on indoor thermal comfort, air quality, and energy-saving potential. The results indicate that, at the same airflow rate, this method effectively maintains high indoor thermal comfort, directs airflow downward from the ceiling, reduces thermal stratification in the upper zone, achieves a more uniform and elevated indoor temperature, enhances indoor air quality, and demonstrates substantial energy-saving potential. This provides valuable insights for energy conservation, emission reduction, and the optimization in winter building ventilation systems.

Energy and BuildingsVol. 324
Zhongyuan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 26%
Wind and Air Flow Studies
1.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.