Analytical Method Development and Validation for Simultaneous Determination of Cabotegravir and Rilpivirine Using RP-HPLC

Type I HIV can be treated by the combination of these drugs. An accurate, precise, and novel RP-HPLC technique was developed and validated for concurrent assessment of cabotegravir and rilpivirine in bulk and medicinal formulation. The separation was achieved by Waters 2695 HPLC system that comprised of PDA detector. Mobile phase was in the ratio of (70:30 v\v) acetonitrile and 0.1N potassium di hydrogen phosphate. Flow rate of 1 ml\min was employed. The detector wavelength was at 257nm.The run time was 5 minutes. The R2 value for cabotegravir was observed to be y=7596.9x+1542.1 and for rilpivirine it was y=7517.8x+5409. LOD values for cabotegravir and rilpivirine were observed to be 0.25 µg/ml and 1.79 µg/ml respectively. LOQ values for cabotegravir and rilpivirine were found to be 0.77 µg/ml and 5.44 µg/ml respectively. The suggested approach was demonstrated to be precise, exact, and ideal for use in quality control laboratories for the quantifiable examination of dosage forms, both singular and mixed.

Authors

Institutions

Publication Details

Journal
Bulletin of Pharmaceutical Sciences Assiut
Published
2024-10-20
DOI
https://doi.org/10.21608/bfsa.2024.308061.2215
Citations
2
Primary Topic
HIV/AIDS drug development and treatment
Type
article
Field-Weighted Citation Impact
0.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development and Validation for Simultaneous Determination of Cabotegravir and Rilpivirine Using RP-HPLC

Raja Sundararajan, Sahitya Bharathi Chodimella
2 citations
Bulletin of Pharmaceutical Sciences Assiut
HIV/AIDS drug development and treatment
0.78
article

Analytical Method Development and Validation for Simultaneous Determination of Cabotegravir and Rilpivirine Using RP-HPLC

Raja Sundararajan, Sahitya Bharathi Chodimella
article en
2 citations

Abstract

Type I HIV can be treated by the combination of these drugs. An accurate, precise, and novel RP-HPLC technique was developed and validated for concurrent assessment of cabotegravir and rilpivirine in bulk and medicinal formulation. The separation was achieved by Waters 2695 HPLC system that comprised of PDA detector. Mobile phase was in the ratio of (70:30 v\v) acetonitrile and 0.1N potassium di hydrogen phosphate. Flow rate of 1 ml\min was employed. The detector wavelength was at 257nm.The run time was 5 minutes. The R2 value for cabotegravir was observed to be y=7596.9x+1542.1 and for rilpivirine it was y=7517.8x+5409. LOD values for cabotegravir and rilpivirine were observed to be 0.25 µg/ml and 1.79 µg/ml respectively. LOQ values for cabotegravir and rilpivirine were found to be 0.77 µg/ml and 5.44 µg/ml respectively. The suggested approach was demonstrated to be precise, exact, and ideal for use in quality control laboratories for the quantifiable examination of dosage forms, both singular and mixed.

Bulletin of Pharmaceutical Sciences AssiutVol. 0(0)
GITAM University (IN)
Zero hunger
Openalex Percentile: Top 27%
HIV/AIDS drug development and treatment
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.