The Operational Stability and Energy Efficiency of Coal-Fired Power Plant Under Ultra-Low Power Load Ratio: Feedwater Preheating System Issues

Abstract The world energy supply continues to evolve and adapt to low carbon and sustainable sources due to energy shortage and environmental issues. As a result, the share of renewable energy sources in the energy mix sharply increases in many countries. However, wind and photovoltaic power is intermittent, and high penetration of renewable power poses high peak shaving pressure on the power system. Therefore, the peak shaving techniques for coal-fired power plant (CFPP) should be developed, aiming to decrease the adjustable minimal power load ratio. When the coal-fired power plant operates under low load ratio, it significantly deviates from the design condition, which will affect the operational safety and economic performances. In this study, the drainage obstruction issues of the feedwater preheating system are analyzed and addressed. Off-design analysis models of coal-fired power plant are developed. Simulation results show that the feedwater preheating system increases the net energy efficiency by 2.90%, 3.11%, 2.49% under 100%, 30% and 20% power load ratio conditions, respectively. The pressure difference between adjacent regenerative heaters (RH) decreases with the load ratio, thus increasing the risk of the drainage obstruction phenomenon. Then, schemes, including the RH’s switch-off, connecting the drainage pipe to deaerator (DRTR) or condenser, or installing the drainage pump (DP) in the drainage pipe are proposed and evaluated. Scheme A connects RH2’s and RH3’s drainage pipes to the DRTR, which can improve the unit’s operational stability and energy efficiency greatly when the drainage obstruction occurs in high-pressure feedwater preheating system. Scheme B connects RH7s and RH8’s drainage pipes to the condenser and Scheme C installs DPs in RH7s and RH8’s drainage pipelines. Scheme B and Scheme C can both enhance the operational stability of low-pressure feedwater preheating system under low load ratio condition. Scheme C have better energy efficiency performance than scheme B, but with more retrofit expense on the pump purchases. Results of this study can provide some guidance for the safe operation of the feedwater preheating system.

Authors

Institutions

Publication Details

Published
2024-09-15
DOI
https://doi.org/10.1115/power2024-137432
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Operational Stability and Energy Efficiency of Coal-Fired Power Plant Under Ultra-Low Power Load Ratio: Feedwater Preheating System Issues

Zeyu Du, Ming Liu, Junjie Yan
Advanced Power Generation Technologies
article

The Operational Stability and Energy Efficiency of Coal-Fired Power Plant Under Ultra-Low Power Load Ratio: Feedwater Preheating System Issues

Zeyu Du, Ming Liu, Junjie Yan
article en

Abstract

Abstract The world energy supply continues to evolve and adapt to low carbon and sustainable sources due to energy shortage and environmental issues. As a result, the share of renewable energy sources in the energy mix sharply increases in many countries. However, wind and photovoltaic power is intermittent, and high penetration of renewable power poses high peak shaving pressure on the power system. Therefore, the peak shaving techniques for coal-fired power plant (CFPP) should be developed, aiming to decrease the adjustable minimal power load ratio. When the coal-fired power plant operates under low load ratio, it significantly deviates from the design condition, which will affect the operational safety and economic performances. In this study, the drainage obstruction issues of the feedwater preheating system are analyzed and addressed. Off-design analysis models of coal-fired power plant are developed. Simulation results show that the feedwater preheating system increases the net energy efficiency by 2.90%, 3.11%, 2.49% under 100%, 30% and 20% power load ratio conditions, respectively. The pressure difference between adjacent regenerative heaters (RH) decreases with the load ratio, thus increasing the risk of the drainage obstruction phenomenon. Then, schemes, including the RH’s switch-off, connecting the drainage pipe to deaerator (DRTR) or condenser, or installing the drainage pump (DP) in the drainage pipe are proposed and evaluated. Scheme A connects RH2’s and RH3’s drainage pipes to the DRTR, which can improve the unit’s operational stability and energy efficiency greatly when the drainage obstruction occurs in high-pressure feedwater preheating system. Scheme B connects RH7s and RH8’s drainage pipes to the condenser and Scheme C installs DPs in RH7s and RH8’s drainage pipelines. Scheme B and Scheme C can both enhance the operational stability of low-pressure feedwater preheating system under low load ratio condition. Scheme C have better energy efficiency performance than scheme B, but with more retrofit expense on the pump purchases. Results of this study can provide some guidance for the safe operation of the feedwater preheating system.

Xi'an Jiaotong University (CN)
Openalex Percentile: Top 84%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.