Experimental Investigation on Vortex Generator's Distance From Film Cooling Hole

Abstract The effects of vortex generator distance from film cooling holes on increasing gas turbine blade film cooling efficiency have been studied experimentally. The technique of infrared (IR) thermography has been implemented to study the temperature field. The diameter of the film cooling hole and the crossflow velocity define the Reynolds number, which is fixed at 2369. There are now three different jets for crossflow blowing ratio adjustments: 0.5, 1.0, and 1.5. Three different vortex generator distances from the film cooling hole have been studied experimentally to increase the gas turbine blade film cooling efficiency. It has been shown that the lowest distance between vortex generator distance and film cooling hole yields better film cooling efficiency. Overall, the delta winglet pair with the lowest distance between vortex generator distance and film cooling hole outperforms the higher distance because of the generation of secondary longitudinal vortices that completely destroy counter-rotating vortex structures because their rotational tendency is opposite to that of the counter-rotating vortex pair (CRVP).

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2024-10-22
DOI
https://doi.org/10.1115/1.4066985
Citations
1
Primary Topic
Fluid Dynamics and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation on Vortex Generator's Distance From Film Cooling Hole

Nirmal Halder
1 citations
Journal of Thermal Science and Engineering Applications
Fluid Dynamics and Vibration Analysis
0.37
article

Experimental Investigation on Vortex Generator's Distance From Film Cooling Hole

Nirmal Halder
article en
1 citations

Abstract

Abstract The effects of vortex generator distance from film cooling holes on increasing gas turbine blade film cooling efficiency have been studied experimentally. The technique of infrared (IR) thermography has been implemented to study the temperature field. The diameter of the film cooling hole and the crossflow velocity define the Reynolds number, which is fixed at 2369. There are now three different jets for crossflow blowing ratio adjustments: 0.5, 1.0, and 1.5. Three different vortex generator distances from the film cooling hole have been studied experimentally to increase the gas turbine blade film cooling efficiency. It has been shown that the lowest distance between vortex generator distance and film cooling hole yields better film cooling efficiency. Overall, the delta winglet pair with the lowest distance between vortex generator distance and film cooling hole outperforms the higher distance because of the generation of secondary longitudinal vortices that completely destroy counter-rotating vortex structures because their rotational tendency is opposite to that of the counter-rotating vortex pair (CRVP).

Journal of Thermal Science and Engineering ApplicationsVol. 17(1)
Sandip Foundation (IN), Indian Institute of Technology Kanpur (IN)
Openalex Percentile: Top 42%
Fluid Dynamics and Vibration Analysis
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.