Comprehensive Geometric Parameterization and Computationally Efficient 3D Shape Matching Optimization of Realistic Stents

Abstract Flexible and compact shape representation schemes are essential for design optimization problems. Current shape representation schemes for coronary stent designs concern predominantly idealized or independent ring (IR) designs, which are outdated and only consider a small number of core design variables (such as strut width, height, and thickness) and ignore clinically critical design characteristics such as the number of connectors. No reports exist on the geometry parameterization of the latest helical stents (HS) that have more complex geometric designs than IR stents. Here, we present two new shape parameterization schemes to fully capture the 3D designs of contemporary IR and double-helix HS stents. We developed a 3D stent geometry builder based on 17 (IR) and 18 (HS) design variables, including strut width, thickness, height, number of connectors and rings, stent length, and strut centerline shape. The shape of the strut centerline was derived via a combination of NURBS, PARSEC, quarter circle, and straight line segments. Shape matching for complex 3D geometries, such as the contemporary stents within limited function evaluations, is not trivial and requires efficient parameterization and optimization algorithms. We used shape matching optimization with a limited function evaluation budget to test the proposed parameterization and two surrogate-assisted optimization algorithms relying on predictor believer and an expected improvement maximization formulation. The performance of these algorithms is objectively compared with a gradient-based optimization method to highlight their strengths. Our work paves the way for more realistic, full-fledged stent design optimization with structural and hemodynamic objectives in the future.

Authors

Institutions

Publication Details

Journal
Journal of Mechanical Design
Published
2024-10-22
DOI
https://doi.org/10.1115/1.4066961
Citations
3
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.75

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Geometric Parameterization and Computationally Efficient 3D Shape Matching Optimization of Realistic Stents

Susann Beier, Tapabrata Ray, Nigel Jepson, Ankush Kapoor
3 citations
Journal of Mechanical Design
Medical Image Segmentation Techniques
0.75
article

Comprehensive Geometric Parameterization and Computationally Efficient 3D Shape Matching Optimization of Realistic Stents

Susann Beier, Tapabrata Ray, Nigel Jepson, Ankush Kapoor
article en
3 citations

Abstract

Abstract Flexible and compact shape representation schemes are essential for design optimization problems. Current shape representation schemes for coronary stent designs concern predominantly idealized or independent ring (IR) designs, which are outdated and only consider a small number of core design variables (such as strut width, height, and thickness) and ignore clinically critical design characteristics such as the number of connectors. No reports exist on the geometry parameterization of the latest helical stents (HS) that have more complex geometric designs than IR stents. Here, we present two new shape parameterization schemes to fully capture the 3D designs of contemporary IR and double-helix HS stents. We developed a 3D stent geometry builder based on 17 (IR) and 18 (HS) design variables, including strut width, thickness, height, number of connectors and rings, stent length, and strut centerline shape. The shape of the strut centerline was derived via a combination of NURBS, PARSEC, quarter circle, and straight line segments. Shape matching for complex 3D geometries, such as the contemporary stents within limited function evaluations, is not trivial and requires efficient parameterization and optimization algorithms. We used shape matching optimization with a limited function evaluation budget to test the proposed parameterization and two surrogate-assisted optimization algorithms relying on predictor believer and an expected improvement maximization formulation. The performance of these algorithms is objectively compared with a gradient-based optimization method to highlight their strengths. Our work paves the way for more realistic, full-fledged stent design optimization with structural and hemodynamic objectives in the future.

Journal of Mechanical DesignVol. 147(5)
University of Canberra (AU), UNSW Sydney (AU), Prince of Wales Hospital (AU), UNSW Canberra
Australian Government, National Heart Foundation of Australia
Openalex Percentile: Top 27%
Medical Image Segmentation Techniques
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.