Target neonatal echocardiography as efficiency assessment method of shock therapy in newborns (a series of clinical observations)

The objective was to demonstrate clinical cases of shock therapy in newborns under the control of target neonatal echocardiography. This method of hemodynamic monitoring is performed at the bedside by intensive care physicians and is available around the clock. Materials and methods. The article describes three clinical cases of shock in newborns whose hemodynamic status was assessed by target neonatal echocardiography. Results. The use of target neonatal echocardiography made it possible to identify a disturbed component of hemodynamics (preload, contractility, postload). In some cases, the actual hemodynamic status differs from the hypothetical one. This made it possible to carry out targeted hemodynamic management and prevent pathogenetically unjustified therapy with potential iatrogenic complications. Conclusion. Target neonatal echocardiography has demonstrated its clinical effectiveness in bedside assessment of hemodynamics in critically ill newborns.

Authors

Institutions

Publication Details

Journal
Messenger of Anesthesiology and Resuscitation
Published
2024-10-19
DOI
https://doi.org/10.24884/2078-5658-2024-21-5-77-83
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Target neonatal echocardiography as efficiency assessment method of shock therapy in newborns (a series of clinical observations)

А. А. Задворнов, А. А. Rudakova, Evgeny V. Grigoryev, A. A. Chernykh
Messenger of Anesthesiology and Resuscitation
Mechanical Circulatory Support Devices
article

Target neonatal echocardiography as efficiency assessment method of shock therapy in newborns (a series of clinical observations)

А. А. Задворнов, А. А. Rudakova, Evgeny V. Grigoryev, A. A. Chernykh
article en

Abstract

The objective was to demonstrate clinical cases of shock therapy in newborns under the control of target neonatal echocardiography. This method of hemodynamic monitoring is performed at the bedside by intensive care physicians and is available around the clock. Materials and methods. The article describes three clinical cases of shock in newborns whose hemodynamic status was assessed by target neonatal echocardiography. Results. The use of target neonatal echocardiography made it possible to identify a disturbed component of hemodynamics (preload, contractility, postload). In some cases, the actual hemodynamic status differs from the hypothetical one. This made it possible to carry out targeted hemodynamic management and prevent pathogenetically unjustified therapy with potential iatrogenic complications. Conclusion. Target neonatal echocardiography has demonstrated its clinical effectiveness in bedside assessment of hemodynamics in critically ill newborns.

Messenger of Anesthesiology and ResuscitationVol. 21(5)
Kemerovo State Medical University (RU), National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of the Russian Federation (RU), Regional Children's Clinical Hospital No. 1 (RU)
Good health and well-being
Openalex Percentile: Top 83%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies