Lateral Glow Discharge Ion Source for the Integrated MEMS Quadrupole Mass Spectrometer

This article presents a glow discharge ion source specifically designed for integration into a fully MEMS-based quadrupole mass spectrometer. The main challenge was to develop an ion source in the form of a multi-layer structure capable of extracting an ion beam in lateral direction and directing it toward the analyzer. Throughout the study, several test structures with varying degrees of complexity were proposed and tested. As anticipated, a trade-off was observed, where successive simplifications of the structure’s geometry led to a reduced operating pressure range and lower emitted ion currents. The structure that proved to be the most technologically compatible with the proposed mass spectrometer demonstrated sufficient efficiency, operating in medium vacuum range (from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 10^{-3}$ </tex-math></inline-formula> hPa) to high vacuum (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1\times 10^{-5}$ </tex-math></inline-formula> hPa), with extracted ion currents reaching tens of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>A.[2024-0140]

Authors

Institutions

Publication Details

Journal
Journal of Microelectromechanical Systems
Published
2024-10-22
DOI
https://doi.org/10.1109/jmems.2024.3477620
Citations
1
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral Glow Discharge Ion Source for the Integrated MEMS Quadrupole Mass Spectrometer

Piotr Szyszka
1 citations
Journal of Microelectromechanical Systems
Plasma Diagnostics and Applications
0.21
article

Lateral Glow Discharge Ion Source for the Integrated MEMS Quadrupole Mass Spectrometer

Piotr Szyszka
article en
1 citations

Abstract

This article presents a glow discharge ion source specifically designed for integration into a fully MEMS-based quadrupole mass spectrometer. The main challenge was to develop an ion source in the form of a multi-layer structure capable of extracting an ion beam in lateral direction and directing it toward the analyzer. Throughout the study, several test structures with varying degrees of complexity were proposed and tested. As anticipated, a trade-off was observed, where successive simplifications of the structure’s geometry led to a reduced operating pressure range and lower emitted ion currents. The structure that proved to be the most technologically compatible with the proposed mass spectrometer demonstrated sufficient efficiency, operating in medium vacuum range (from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 10^{-3}$ </tex-math></inline-formula> hPa) to high vacuum (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1\times 10^{-5}$ </tex-math></inline-formula> hPa), with extracted ion currents reaching tens of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu $ </tex-math></inline-formula>A.[2024-0140]

Journal of Microelectromechanical SystemsVol. 34(1)
AGH University of Krakow (PL)
Narodowe Centrum Nauki
Openalex Percentile: Top 47%
Plasma Diagnostics and Applications
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lateral Glow Discharge Ion Source for the Integrated MEMS Quadrupole Mass Spectrometer — Piotr Szyszka · Journal of Microelectromechanical Systems (2024) | TGRS Research Map | TGRS