Optimization of carbon dioxide adsorption from industrial flue gas using zeolite 13X: A simulation study with Aspen Adsorption and response surface methodology

• To remove CO 2 gas from the desired gas mixture, an adsorption operation unit with a column filled with zeolite 13X adsorbent was simulated in Aspen Adsorption. • The adsorption unit was optimized by RSM to achieve maximum CO 2 adsorption. • Temperature and mole fraction of CO 2 were identified as key influencing factors determining the adsorption performance of zeolite 13X for CO 2 adsorption. • the system should be operated at a temperature of 28.07 °C and a pressure of 1.202 bar to achieve maximum adsorption. • Adsorption of 2.784 mole CO 2 gas was captured by the process in optimal operating conditions. One of the best ways to prevent further warming of the planet and reduce pollutants is to remove or adsorb and recover carbon dioxide gas from the exit of cement factory exhaust. So far, several methods have been proposed for this; In this research, zeolite 13X adsorbent is used considering the operational conditions. To remove CO 2 gas from the desired gas mixture, an adsorption operation unit with a column filled with zeolite 13X adsorbent was simulated in Aspen Adsorption V14 software. Changes in parameters such as temperature, and pressure and their effects on adsorption rate, adsorbent saturation time, and output heat rate were investigated to achieve higher system efficiency and optimal operating conditions. The adsorption unit was optimized by RSM to achieve maximum CO 2 adsorption. Temperature and mole fraction of CO 2 were identified as key influencing factors determining the adsorption performance of zeolite 13X for CO 2 adsorption. It was found that the system should be operated at a temperature of 28.07 °C and a pressure of 1.202 bar to achieve maximum adsorption. Finally, 2.784 mol% CO 2 gas was captured by the said process in optimal operating conditions. Further analysis revealed higher temperatures slightly decrease CO 2 adsorption capacity, while increasing pressure enhances it. Conversely, elevated flow rates reduce breakthrough time, indicating a trade-off between adsorption capacity and capture efficiency.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-10-22
DOI
https://doi.org/10.1016/j.rineng.2024.103206
Citations
17
Primary Topic
Carbon Dioxide Capture Technologies
Type
article
Field-Weighted Citation Impact
3.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of carbon dioxide adsorption from industrial flue gas using zeolite 13X: A simulation study with Aspen Adsorption and response surface methodology

Ahad Ghaemi, Fatemeh Afshari, Narges Nazari, Mahdi Mahmoudkhani
17 citations
Results in Engineering
Carbon Dioxide Capture Technologies
3.61
article

Optimization of carbon dioxide adsorption from industrial flue gas using zeolite 13X: A simulation study with Aspen Adsorption and response surface methodology

Ahad Ghaemi, Fatemeh Afshari, Narges Nazari, Mahdi Mahmoudkhani
article en
17 citations

Abstract

• To remove CO 2 gas from the desired gas mixture, an adsorption operation unit with a column filled with zeolite 13X adsorbent was simulated in Aspen Adsorption. • The adsorption unit was optimized by RSM to achieve maximum CO 2 adsorption. • Temperature and mole fraction of CO 2 were identified as key influencing factors determining the adsorption performance of zeolite 13X for CO 2 adsorption. • the system should be operated at a temperature of 28.07 °C and a pressure of 1.202 bar to achieve maximum adsorption. • Adsorption of 2.784 mole CO 2 gas was captured by the process in optimal operating conditions. One of the best ways to prevent further warming of the planet and reduce pollutants is to remove or adsorb and recover carbon dioxide gas from the exit of cement factory exhaust. So far, several methods have been proposed for this; In this research, zeolite 13X adsorbent is used considering the operational conditions. To remove CO 2 gas from the desired gas mixture, an adsorption operation unit with a column filled with zeolite 13X adsorbent was simulated in Aspen Adsorption V14 software. Changes in parameters such as temperature, and pressure and their effects on adsorption rate, adsorbent saturation time, and output heat rate were investigated to achieve higher system efficiency and optimal operating conditions. The adsorption unit was optimized by RSM to achieve maximum CO 2 adsorption. Temperature and mole fraction of CO 2 were identified as key influencing factors determining the adsorption performance of zeolite 13X for CO 2 adsorption. It was found that the system should be operated at a temperature of 28.07 °C and a pressure of 1.202 bar to achieve maximum adsorption. Finally, 2.784 mol% CO 2 gas was captured by the said process in optimal operating conditions. Further analysis revealed higher temperatures slightly decrease CO 2 adsorption capacity, while increasing pressure enhances it. Conversely, elevated flow rates reduce breakthrough time, indicating a trade-off between adsorption capacity and capture efficiency.

Results in EngineeringVol. 24
Iran University of Science and Technology (IR)
Openalex Percentile: Top 6%
Carbon Dioxide Capture Technologies
3.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.