Diagnostic accuracy of the lactate stress test for detecting mitochondrial disorders: Systematic review and meta-analysis

Due to their variable phenotypes, mitochondrial disorders (MDs) can be difficult to diagnose. The absolute load lactate stress test (LSTA) and the relative load lactate stress test (LSTR) have been shown to be useful screening tools for the detection of MDs. In this study, we aimed to perform a meta-analysis to evaluate the diagnostic accuracy of these tests in detecting MDs. The study protocol was registered with PROSPERO (no. CRD42022331710). We performed a comprehensive search of PubMed, Web of Science and Scopus from January 10th, 2022 to July 27th, 2022 and included case-control and cohort diagnostic studies that targeted participants with MDs and used LSTA and/or LSTR as index tests. Two reviewers worked separately to compile information from selected articles. Risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity, as well as diagnostic odds ratios (DORs) and area under the curve (AUC) were calculated using Meta-DiSc 2.0 and Stata software. The analysis included 14 studies with a total of 1064 participants, divided into six studies with 793 participants for LSTA and eight studies with 271 participants for LSTR. For LSTA the meta-analysis gave a pooled sensitivity of 0.67 (95 % CI 0.62, 0.72), a specificity of 0.93 (95 % CI 0.85, 0.97), DOR of 26.63 (95 % CI 10.99, 64.52), and AUC of 0.70 (95 % CI 0.66, 0.74). For LSTR, the pooled sensitivity was 0.52 (95 % CI 0.33, 0.70), specificity 0.94 (95 % CI 0.79, 0.99), DOR 18.14 (95 % CI 2.99, 109.85), and the AUC 0.80 (95 % CI 0.76, 0.83). LSTA and LSTR showed as screening tests moderate sensitivity and high specificity for MD diagnosis, particularly for LSTR. The choice of test may depend on the patient's individual aerobic capacity and motor skills and the availability of equipment.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-10-22
DOI
https://doi.org/10.1016/j.heliyon.2024.e39648
Citations
1
Primary Topic
Mitochondrial Function and Pathology
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic accuracy of the lactate stress test for detecting mitochondrial disorders: Systematic review and meta-analysis

Yamna Kriouile, Azeddine Ibrahimi, Fatima Sfifou, Josef Finsterer et al.
1 citations
Heliyon
Mitochondrial Function and Pathology
0.23
article

Diagnostic accuracy of the lactate stress test for detecting mitochondrial disorders: Systematic review and meta-analysis

Yamna Kriouile, Azeddine Ibrahimi, Fatima Sfifou, Josef Finsterer, Rédouane Abouqal, Ghizlane Zouiri, Sara El Guessabi
article en
1 citations

Abstract

Due to their variable phenotypes, mitochondrial disorders (MDs) can be difficult to diagnose. The absolute load lactate stress test (LSTA) and the relative load lactate stress test (LSTR) have been shown to be useful screening tools for the detection of MDs. In this study, we aimed to perform a meta-analysis to evaluate the diagnostic accuracy of these tests in detecting MDs. The study protocol was registered with PROSPERO (no. CRD42022331710). We performed a comprehensive search of PubMed, Web of Science and Scopus from January 10th, 2022 to July 27th, 2022 and included case-control and cohort diagnostic studies that targeted participants with MDs and used LSTA and/or LSTR as index tests. Two reviewers worked separately to compile information from selected articles. Risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity, as well as diagnostic odds ratios (DORs) and area under the curve (AUC) were calculated using Meta-DiSc 2.0 and Stata software. The analysis included 14 studies with a total of 1064 participants, divided into six studies with 793 participants for LSTA and eight studies with 271 participants for LSTR. For LSTA the meta-analysis gave a pooled sensitivity of 0.67 (95 % CI 0.62, 0.72), a specificity of 0.93 (95 % CI 0.85, 0.97), DOR of 26.63 (95 % CI 10.99, 64.52), and AUC of 0.70 (95 % CI 0.66, 0.74). For LSTR, the pooled sensitivity was 0.52 (95 % CI 0.33, 0.70), specificity 0.94 (95 % CI 0.79, 0.99), DOR 18.14 (95 % CI 2.99, 109.85), and the AUC 0.80 (95 % CI 0.76, 0.83). LSTA and LSTR showed as screening tests moderate sensitivity and high specificity for MD diagnosis, particularly for LSTR. The choice of test may depend on the patient's individual aerobic capacity and motor skills and the availability of equipment.

HeliyonVol. 10(21)
Mohammed V University (MA), École des Hautes Études Commerciales (MA)
Zero hunger
Openalex Percentile: Top 42%
Mitochondrial Function and Pathology
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.