Predictive building energy management with user feedback in the loop

Retrofitting buildings with predictive control strategies can reduce their energy demand and improve thermal comfort by considering their thermal inertia and future weather conditions. A key challenge is minimizing additional infrastructure, such as sensors and actuators, while ensuring user comfort at all times. This study focuses on retrofitting with intelligent software, incorporating the users’ feedback directly into the control loop. We propose a predictive control strategy using an optimization-based energy management system (EMS) to control thermal zones in an office building. It uses a physically motivated grey-box model to predict and adjust thermal demand, with individual zones modelled using an RC-approach and parameter estimation handled by an unscented Kalman filter (UKF). This reduces deployment effort as the parameters are learned from historical data. The objective function ensures user comfort, penalizes undesirable behaviour and minimizes heating and cooling costs. An internal comfort model, automatically calibrated with user feedback by another UKF, further improves system performance. The practical case study is an office building at the ”Innovation District Inffeld”. Operation of the system for one year yielded significant results compared to conventional control. Thermal comfort was improved by 12% and thermal energy consumption for heating and cooling was reduced by about 35%. • Smart, predictive building energy management. • Model-based consideration of user feedback in the objective function. • Implementation and long-term validation at office building at Campus Inffeldgasse TU Graz. • Comfort Improvement of 12% and energy reduction of 35%.

Authors

Institutions

Publication Details

Journal
Smart Energy
Published
2024-10-22
DOI
https://doi.org/10.1016/j.segy.2024.100164
Citations
7
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictive building energy management with user feedback in the loop

Gerald Schweiger, Valentin Kaisermayer, Martin Horn, Markus Gölles et al.
7 citations
Smart Energy
Building Energy and Comfort Optimization
1.86
article

Predictive building energy management with user feedback in the loop

Gerald Schweiger, Valentin Kaisermayer, Martin Horn, Markus Gölles, Richard Heimrath, Daniel Muschick, Thomas Mach, Thomas Schwengler, Michael Mörth, Michael Herzlieb
article en
7 citations

Abstract

Retrofitting buildings with predictive control strategies can reduce their energy demand and improve thermal comfort by considering their thermal inertia and future weather conditions. A key challenge is minimizing additional infrastructure, such as sensors and actuators, while ensuring user comfort at all times. This study focuses on retrofitting with intelligent software, incorporating the users’ feedback directly into the control loop. We propose a predictive control strategy using an optimization-based energy management system (EMS) to control thermal zones in an office building. It uses a physically motivated grey-box model to predict and adjust thermal demand, with individual zones modelled using an RC-approach and parameter estimation handled by an unscented Kalman filter (UKF). This reduces deployment effort as the parameters are learned from historical data. The objective function ensures user comfort, penalizes undesirable behaviour and minimizes heating and cooling costs. An internal comfort model, automatically calibrated with user feedback by another UKF, further improves system performance. The practical case study is an office building at the ”Innovation District Inffeld”. Operation of the system for one year yielded significant results compared to conventional control. Thermal comfort was improved by 12% and thermal energy consumption for heating and cooling was reduced by about 35%. • Smart, predictive building energy management. • Model-based consideration of user feedback in the objective function. • Implementation and long-term validation at office building at Campus Inffeldgasse TU Graz. • Comfort Improvement of 12% and energy reduction of 35%.

Smart EnergyVol. 16
Mercedes-Benz (Germany) (DE), Graz University of Technology (AT), BEST - Bioenergy and Sustainable Technologies (Austria) (AT), Anstalt für Verbrennungskraftmaschinen List (Austria) (AT)
Affordable and clean energy
Openalex Percentile: Top 16%
Building Energy and Comfort Optimization
1.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.