Determination of the ambient dose equivalent <i>H</i>*(10) at high-altitude cities using a NaI(Tl) scintillator

The ambient dose equivalent rate H*(10) was determined at various locations in the metropolitan area of the cities of La Paz and El Alto in Bolivia. A NaI(Tl) scintillation detector was employed to infer the gamma-ray fluence, and the fluence was transformed in dose rates by means of the appropriate coefficients. In this paper, a full methodology for the estimation of dose rates associated with gamma rays emitted from the ground (terrestrial radiation) and the atmosphere is developed from measurements made with the scintillator instrument. The energy calibration and resolution of the apparatus are presented, followed by the estimation of its response and efficiency by means of Monte Carlo simulations. Lastly, the definition of H*(10) is used to determine the conversion coefficients needed to transform gamma-ray fluence in dose rates. With this methodology, rates for H*(10) around 123 ± 8 nSv/h were estimated using data collected in three city districts: Mallasa (3320 m a.s.l.), San Antonio (3620 m a.s.l.), and Zona Sur (3400 m a.s.l.). The dose rates are believed to be representative of the terrestrial radiation fields encountered in the highlands of Bolivia.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-10-22
DOI
https://doi.org/10.1093/rpd/ncae209
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the ambient dose equivalent H*(10) at high-altitude cities using a NaI(Tl) scintillator

Carlos Lorenzo Nina Choque, Hugo Marcelo Rivera Bretel
1 citations
Radiation Protection Dosimetry
Radiation Detection and Scintillator Technologies
0.61
article

Determination of the ambient dose equivalent H*(10) at high-altitude cities using a NaI(Tl) scintillator

Carlos Lorenzo Nina Choque, Hugo Marcelo Rivera Bretel
article en
1 citations

Abstract

The ambient dose equivalent rate H*(10) was determined at various locations in the metropolitan area of the cities of La Paz and El Alto in Bolivia. A NaI(Tl) scintillation detector was employed to infer the gamma-ray fluence, and the fluence was transformed in dose rates by means of the appropriate coefficients. In this paper, a full methodology for the estimation of dose rates associated with gamma rays emitted from the ground (terrestrial radiation) and the atmosphere is developed from measurements made with the scintillator instrument. The energy calibration and resolution of the apparatus are presented, followed by the estimation of its response and efficiency by means of Monte Carlo simulations. Lastly, the definition of H*(10) is used to determine the conversion coefficients needed to transform gamma-ray fluence in dose rates. With this methodology, rates for H*(10) around 123 ± 8 nSv/h were estimated using data collected in three city districts: Mallasa (3320 m a.s.l.), San Antonio (3620 m a.s.l.), and Zona Sur (3400 m a.s.l.). The dose rates are believed to be representative of the terrestrial radiation fields encountered in the highlands of Bolivia.

Radiation Protection DosimetryVol. 200(20)
Universidad Mayor de San Andrés (BO)
Sustainable cities and communities
Openalex Percentile: Top 30%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.