Reliably estimating the impact of an active control strategy in a building

Conventional measurement and verification (M&V) methods rely on a pre-/post-intervention analysis that generally take a long time (2 years) to estimate energy savings. Further, results are often affected by changes in building performance that are unrelated to the intervention but that occur over that timeframe. This paper describes a new method which applies to interventions that are easily switchable, such as active control strategies, and which overcomes these limitations. It uses a switchback design that randomly and frequently switches building operations between baseline and intervention strategies at fixed time intervals (e.g., daily). The method uses sequential testing to evaluate pre-defined stopping criteria using measurements obtained by that point in time. Upon satisfying all criteria, the analyst reports savings with an associated uncertainty. The paper demonstrates the method by evaluating a control strategy developed by a software-as-a-service company in a case study building in Chicago, IL, USA. It provides guidance on randomization and blocking, selection of meaningful stopping criteria, implementation of sequential evaluation, and annual weather normalization. The results show that all pre-defined thresholds were satisfied after 45 weeks and the method reliably detected an annual average power savings of 7 kW (±5 kW at 90 % confidence), or 11 % annual energy savings when weather normalized. This result was obtained faster and more robustly than conventional methods, and remained consistent with estimates derived from a further 15 weeks of data. The supplementary material includes example software code to apply this method to other case studies and replicate this analysis. • Addressed drawbacks of conventional measurement and verification methods. • Developed a new method that randomly and frequently switches control strategies. • The method applies to a variety of performance metrics and use cases. • Increases robustness by sequentially testing against pre-defined stopping criteria. • A case study showed improved uncertainty quantification in a reduced timeline.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-10-22
DOI
https://doi.org/10.1016/j.jobe.2024.111134
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliably estimating the impact of an active control strategy in a building

Paul Raftery, Thomas Parkinson, Aoyu Zou, G. Hancock
2 citations
Journal of Building Engineering
Building Energy and Comfort Optimization
0.53
article

Reliably estimating the impact of an active control strategy in a building

Paul Raftery, Thomas Parkinson, Aoyu Zou, G. Hancock
article en
2 citations

Abstract

Conventional measurement and verification (M&V) methods rely on a pre-/post-intervention analysis that generally take a long time (2 years) to estimate energy savings. Further, results are often affected by changes in building performance that are unrelated to the intervention but that occur over that timeframe. This paper describes a new method which applies to interventions that are easily switchable, such as active control strategies, and which overcomes these limitations. It uses a switchback design that randomly and frequently switches building operations between baseline and intervention strategies at fixed time intervals (e.g., daily). The method uses sequential testing to evaluate pre-defined stopping criteria using measurements obtained by that point in time. Upon satisfying all criteria, the analyst reports savings with an associated uncertainty. The paper demonstrates the method by evaluating a control strategy developed by a software-as-a-service company in a case study building in Chicago, IL, USA. It provides guidance on randomization and blocking, selection of meaningful stopping criteria, implementation of sequential evaluation, and annual weather normalization. The results show that all pre-defined thresholds were satisfied after 45 weeks and the method reliably detected an annual average power savings of 7 kW (±5 kW at 90 % confidence), or 11 % annual energy savings when weather normalized. This result was obtained faster and more robustly than conventional methods, and remained consistent with estimates derived from a further 15 weeks of data. The supplementary material includes example software code to apply this method to other case studies and replicate this analysis. • Addressed drawbacks of conventional measurement and verification methods. • Developed a new method that randomly and frequently switches control strategies. • The method applies to a variety of performance metrics and use cases. • Increases robustness by sequentially testing against pre-defined stopping criteria. • A case study showed improved uncertainty quantification in a reduced timeline.

Journal of Building EngineeringVol. 98
Faculty of Design (SI), University of California, Berkeley (US)
Climate action
Openalex Percentile: Top 34%
Building Energy and Comfort Optimization
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.