Management of a fractured microcatheter during middle meningeal artery embolization

Middle meningeal artery embolization (MMAE) is an effective adjunctive treatment for chronic subdural hematomas and carries a low risk of significant complications.1 Here we describe the management of a retained and fractured microcatheter following liquid embolic MMAE. A patient with chronic recurrent subdural hematomas underwent bilateral MMAE with Onyx liquid embolic material (Medtronic). The Headway Duo (Microvention) microcatheter was placed in a small distal frontal branch of the middle meningeal artery to aid in reflux into the posterior middle meningeal artery branches. Following successful MMAE, the microcatheter became trapped within the Onyx cast and, on attempted removal, the microcatheter fractured, resulting in a retained fragment extending from the middle meningeal artery cast to the guide catheter in the common carotid artery.To retrieve the fractured microcatheter, a stent retriever was deployed and resheathed multiple times until the retained microcatheter became visibly entangled with the stent retriever. Next, the stent retriever was pulled back into the guide catheter and continuous aspiration was performed through the guide catheter, and the fragmented microcatheter was successfully removed in entirety. Final angiography demonstrated no further catheter fragments, vessel damage, extravasation, flow limitation, or thromboembolic complications.Methods to avoid the complication include using a detachable tip microcatheter, dual lumen balloon microcatheter, allowing less reflux, embolizing from a larger caliber branch, and a slower microcatheter pull. Additional methods for managing the complication include using a snare, leaving the retained microcatheter and putting the patient on aspirin, and carotid stenting to tack the fractured portion down (video 1). neurintsurg;16/12/1214/V1F1V1Video 1 Management of a fractured microcatheter during middle meningeal artery embolization This case demonstrates the successful use of a stent retriever and aspiration to retrieve a retained and fractured microcatheter following liquid embolic MMAE.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2024-10-20
DOI
https://doi.org/10.1136/jnis-2024-022279
Citations
1
Primary Topic
Neurosurgical Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Management of a fractured microcatheter during middle meningeal artery embolization

Fadi Al Saiegh, Cristian Gragnaniello, Justin Robert Mascitelli, M Webb et al.
1 citations
Journal of NeuroInterventional Surgery
Neurosurgical Procedures and Complications
0.37
article

Management of a fractured microcatheter during middle meningeal artery embolization

Fadi Al Saiegh, Cristian Gragnaniello, Justin Robert Mascitelli, M Webb, Allison Luo, Lee Birnbaum
article en
1 citations

Abstract

Middle meningeal artery embolization (MMAE) is an effective adjunctive treatment for chronic subdural hematomas and carries a low risk of significant complications.1 Here we describe the management of a retained and fractured microcatheter following liquid embolic MMAE. A patient with chronic recurrent subdural hematomas underwent bilateral MMAE with Onyx liquid embolic material (Medtronic). The Headway Duo (Microvention) microcatheter was placed in a small distal frontal branch of the middle meningeal artery to aid in reflux into the posterior middle meningeal artery branches. Following successful MMAE, the microcatheter became trapped within the Onyx cast and, on attempted removal, the microcatheter fractured, resulting in a retained fragment extending from the middle meningeal artery cast to the guide catheter in the common carotid artery.To retrieve the fractured microcatheter, a stent retriever was deployed and resheathed multiple times until the retained microcatheter became visibly entangled with the stent retriever. Next, the stent retriever was pulled back into the guide catheter and continuous aspiration was performed through the guide catheter, and the fragmented microcatheter was successfully removed in entirety. Final angiography demonstrated no further catheter fragments, vessel damage, extravasation, flow limitation, or thromboembolic complications.Methods to avoid the complication include using a detachable tip microcatheter, dual lumen balloon microcatheter, allowing less reflux, embolizing from a larger caliber branch, and a slower microcatheter pull. Additional methods for managing the complication include using a snare, leaving the retained microcatheter and putting the patient on aspirin, and carotid stenting to tack the fractured portion down (video 1). neurintsurg;16/12/1214/V1F1V1Video 1 Management of a fractured microcatheter during middle meningeal artery embolization This case demonstrates the successful use of a stent retriever and aspiration to retrieve a retained and fractured microcatheter following liquid embolic MMAE.

Journal of NeuroInterventional SurgeryVol. 16(12)
The University of Texas at San Antonio Health Science Center (US), Urology San Antonio (US)
Good health and well-being
Openalex Percentile: Top 34%
Neurosurgical Procedures and Complications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.