Removal of errant coils using the Tigertriever-13

Coil migration poses a significant intraprocedural risk during coil embolization in interventional neuroradiology procedures. In this technical video we describe the technique of removal of errand coils using the low profile Tigertriever-13 device.1 Traditional methods of errant coil retrieval rely on the use of stent retrievers;2 however, these devices are usually too large to fit through smaller inner diameter 0.013-0.0165 inch coiling catheters, thus requiring upsizing materials in emergency situations.3 We demonstrate the technique of coil retrieval using this low-profile device ex-vivo in silicone flow models, then its application in vivo as a 'bail-out' technique during acute embolization of a ruptured peri-callosal aneurysm which required retrieval of errant coils (video 1). neurintsurg;16/12/1212/V1F1V1Video 1Errant coil retrieval using the Tigertriever device.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2024-10-20
DOI
https://doi.org/10.1136/jnis-2024-021923
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Removal of errant coils using the Tigertriever-13

Emily Chung, Pascal J. Mosimann, Hugo Boechat Andrade, Andrew Falzon et al.
Journal of NeuroInterventional Surgery
Intracranial Aneurysms: Treatment and Complications
article

Removal of errant coils using the Tigertriever-13

Emily Chung, Pascal J. Mosimann, Hugo Boechat Andrade, Andrew Falzon, Shah Islam, Ze'ev Itzakzonhayosh
article en

Abstract

Coil migration poses a significant intraprocedural risk during coil embolization in interventional neuroradiology procedures. In this technical video we describe the technique of removal of errand coils using the low profile Tigertriever-13 device.1 Traditional methods of errant coil retrieval rely on the use of stent retrievers;2 however, these devices are usually too large to fit through smaller inner diameter 0.013-0.0165 inch coiling catheters, thus requiring upsizing materials in emergency situations.3 We demonstrate the technique of coil retrieval using this low-profile device ex-vivo in silicone flow models, then its application in vivo as a 'bail-out' technique during acute embolization of a ruptured peri-callosal aneurysm which required retrieval of errant coils (video 1). neurintsurg;16/12/1212/V1F1V1Video 1Errant coil retrieval using the Tigertriever device.

Journal of NeuroInterventional SurgeryVol. 16(12)
University Health Network (CA), Toronto Western Hospital (CA)
Openalex Percentile: Top 71%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Removal of errant coils using the Tigertriever-13 — Emily Chung, Pascal J. Mosimann, et al. · Journal of NeuroInterventional Surgery (2024) | TGRS Research Map | TGRS