Reproducibility Of Retinal Nerve Fiber Layer And Macular Volume Measurements In Patients Receiving Retinal Protection Pharmacotherapy

Background — High-quality monitoring of the glaucoma plays an important role in the early diagnosis and treatment of glaucoma, for which structural optical coherence tomography (OCT) is used. Technology that increases the repeatability and reproducibility of OCT may differ in different devices, thereby yielding different results. Objective — To assess the effect of the frequency of retinal protection pharmacotherapy courses on quantitative data regarding the macular volume and the thickness of the retinal nerve fiber layer (RNFL) measured by two instruments, SPECTRALIS and OPTOPOL, and also to evaluate the agreement between the data collected by these devices. Material and Methods — We monitored 17 patients (34 eyes) diagnosed with primary open-angle glaucoma in the advanced stage from 2019 to 2023. Group 1 including 9 patients (18 eyes) received a course of retinal protection pharmacotherapy with Retinalamin® at an interval of 3 months, while Group 2 comprising 8 patients (16 eyes) received similar treatment at an interval of 6 months. All observed patients underwent structural OCT on REVO NX (OPTOPOL Technology) and SPECTRALIS devices at the onset of the study, as well as after 3 and 6 months. Results — The agreement between the two devices in measuring RNFL thickness was estimated by the Lin’s concordance correlation coefficient (LCCC): in manual mode, LCCCstart=0.69 (95% CI: 0.51-0.81); while in automatic mode, LCCCstart=0.73 (95% CI: 0.57-0.84). The agreement between the macular volume measurements was as follows: in manual mode, LCCCstart=0.21 (95% CI: 0.21-0.29); while in automatic mode, LCCCstart=0.21 (95% CI: 0.21-0.29). Conclusion — The agreement between the SPECTRALIS and OPTOPOL devices in terms of RNFL thickness should be considered substantial, while in terms of macular volume, it should be classified as fair. As measured in the manual mode, the RNFL thickness in both groups receiving Retinalamin increased, which can be interpreted as a favorable effect of retinal protection pharmacotherapy.

Authors

Institutions

Publication Details

Journal
Russian Open Medical Journal
Published
2024-09-30
DOI
https://doi.org/10.15275/rusomj.2024.0307
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility Of Retinal Nerve Fiber Layer And Macular Volume Measurements In Patients Receiving Retinal Protection Pharmacotherapy

A Z Ciganov, Olga B. Solovieva, Д. А. Дорофеев, А. А. Витков et al.
Russian Open Medical Journal
Glaucoma and retinal disorders
article

Reproducibility Of Retinal Nerve Fiber Layer And Macular Volume Measurements In Patients Receiving Retinal Protection Pharmacotherapy

A Z Ciganov, Olga B. Solovieva, Д. А. Дорофеев, А. А. Витков, Elena V. Kirilik, О. Г. Поздеева, I.V. Kozlova, Lukyanova Ksenia O.
article en

Abstract

Background — High-quality monitoring of the glaucoma plays an important role in the early diagnosis and treatment of glaucoma, for which structural optical coherence tomography (OCT) is used. Technology that increases the repeatability and reproducibility of OCT may differ in different devices, thereby yielding different results. Objective — To assess the effect of the frequency of retinal protection pharmacotherapy courses on quantitative data regarding the macular volume and the thickness of the retinal nerve fiber layer (RNFL) measured by two instruments, SPECTRALIS and OPTOPOL, and also to evaluate the agreement between the data collected by these devices. Material and Methods — We monitored 17 patients (34 eyes) diagnosed with primary open-angle glaucoma in the advanced stage from 2019 to 2023. Group 1 including 9 patients (18 eyes) received a course of retinal protection pharmacotherapy with Retinalamin® at an interval of 3 months, while Group 2 comprising 8 patients (16 eyes) received similar treatment at an interval of 6 months. All observed patients underwent structural OCT on REVO NX (OPTOPOL Technology) and SPECTRALIS devices at the onset of the study, as well as after 3 and 6 months. Results — The agreement between the two devices in measuring RNFL thickness was estimated by the Lin’s concordance correlation coefficient (LCCC): in manual mode, LCCCstart=0.69 (95% CI: 0.51-0.81); while in automatic mode, LCCCstart=0.73 (95% CI: 0.57-0.84). The agreement between the macular volume measurements was as follows: in manual mode, LCCCstart=0.21 (95% CI: 0.21-0.29); while in automatic mode, LCCCstart=0.21 (95% CI: 0.21-0.29). Conclusion — The agreement between the SPECTRALIS and OPTOPOL devices in terms of RNFL thickness should be considered substantial, while in terms of macular volume, it should be classified as fair. As measured in the manual mode, the RNFL thickness in both groups receiving Retinalamin increased, which can be interpreted as a favorable effect of retinal protection pharmacotherapy.

Russian Open Medical JournalVol. 13(3)
Chelyabinsk State Medical Academy (RU), Federal State Scientific Institution Research Institute of Eye Diseases (RU), Intersectoral Research and Technology Complex Eye Microsurgery (RU), Municipal Autonomous Healthcare Institution (RU)
Openalex Percentile: Top 69%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.