Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction

This study introduces a novel framework to apply the artifact subspace reconstruction (ASR) algorithm on single-channel electroencephalogram (EEG) data. ASR is known for its ability to remove artifacts like eye-blinks and movement but traditionally relies on multiple channels. Embedded ASR (E-ASR) addresses this by incorporating a dynamical embedding approach. In this method, an embedded matrix is created from single-channel EEG data using delay vectors, followed by ASR application and reconstruction of the cleaned signal. Data from four subjects with eyes open were collected using Fp1 and Fp2 electrodes via the CameraEEG android app. The E-ASR algorithm was evaluated using metrics like relative root mean square error (RRMSE), correlation coefficient (CC), and average power ratio. The number of eye-blinks with and without the E-ASR approach was also estimated. E-ASR achieved an RRMSE of 43.87% and had a CC of 0.91 on semi-simulated data and effectively reduced artifacts in real EEG data, with eye-blink counts validated against ground truth video data. This framework shows potential for smartphone-based EEG applications in natural environments with minimal electrodes.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-10-19
DOI
https://doi.org/10.3390/s24206734
Citations
2
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction

Cota Navin Gupta, Kartikey Vishnu, Ramdas Ransing, Doli Hazarika
2 citations
Sensors
EEG and Brain-Computer Interfaces
0.69
article

Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction

Cota Navin Gupta, Kartikey Vishnu, Ramdas Ransing, Doli Hazarika
article en
2 citations

Abstract

This study introduces a novel framework to apply the artifact subspace reconstruction (ASR) algorithm on single-channel electroencephalogram (EEG) data. ASR is known for its ability to remove artifacts like eye-blinks and movement but traditionally relies on multiple channels. Embedded ASR (E-ASR) addresses this by incorporating a dynamical embedding approach. In this method, an embedded matrix is created from single-channel EEG data using delay vectors, followed by ASR application and reconstruction of the cleaned signal. Data from four subjects with eyes open were collected using Fp1 and Fp2 electrodes via the CameraEEG android app. The E-ASR algorithm was evaluated using metrics like relative root mean square error (RRMSE), correlation coefficient (CC), and average power ratio. The number of eye-blinks with and without the E-ASR approach was also estimated. E-ASR achieved an RRMSE of 43.87% and had a CC of 0.91 on semi-simulated data and effectively reduced artifacts in real EEG data, with eye-blink counts validated against ground truth video data. This framework shows potential for smartphone-based EEG applications in natural environments with minimal electrodes.

SensorsVol. 24(20)
Indian Institute of Technology Guwahati (IN), All India Institute of Medical Sciences Guwahati (IN)
Openalex Percentile: Top 30%
EEG and Brain-Computer Interfaces
0.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.