Generalized volumetric energy balance for directly irradiated bubbling fluidized beds

• A fluidized particle receiver for beam-down concentrating solar power is studied. • Open and closed bubbling fluidized bed receivers are irradiated to the bed surface. • A correlation to estimate the bed surface emissivity is proposed and validated. • The methodology to apply a simplified bed energy balance is explained. • The new approach simplifies the thermal design of the receiver at steady state. Beam-down concentrating solar towers are receiving much attention from the scientific and industry sectors to generate electricity, produce chemical fuels, and drive energy-intensive processing of materials. The easy thermal design of the solar receiver is essential for the deployment of this renewable energy. This work proposes the equations and methodology to solve the steady-state energy balance of directly irradiated bubbling fluidized beds. The analysis focuses on solving the heating of the bed surface assuming that the energy flux received at the bed surface is absorbed through a layer of particles. The proposed methodology considers a volumetric energy balance of the top-bed surface to calculate the bed temperature. The bed surface emissivity ( ε b ) is a critical parameter in order to solve such an energy balance. To deal with the radiative losses, a correlation is proposed to estimate bed emissivity at the top-bed surface that depends on the dimensionless length number, d p * = A r 1 3 . The results are validated against both new experimental and literature data for the open and closed fluidized bed receivers. The absolute relative error when estimating the steady state temperature of the systems studied is about 5.2 % (on average). The relative error follows a Gaussian distribution guaranteeing an unbiased estimation of the bed temperatures at steady-state operation.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2024-10-20
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2024.126313
Citations
5
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
1.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generalized volumetric energy balance for directly irradiated bubbling fluidized beds

M. Díaz-Heras, Jesús Gómez-Hernández, Javier Villa Briongos, J.A. Almendros-Ibáñez
5 citations
International Journal of Heat and Mass Transfer
Cyclone Separators and Fluid Dynamics
1.87
article

Generalized volumetric energy balance for directly irradiated bubbling fluidized beds

M. Díaz-Heras, Jesús Gómez-Hernández, Javier Villa Briongos, J.A. Almendros-Ibáñez
article en
5 citations

Abstract

• A fluidized particle receiver for beam-down concentrating solar power is studied. • Open and closed bubbling fluidized bed receivers are irradiated to the bed surface. • A correlation to estimate the bed surface emissivity is proposed and validated. • The methodology to apply a simplified bed energy balance is explained. • The new approach simplifies the thermal design of the receiver at steady state. Beam-down concentrating solar towers are receiving much attention from the scientific and industry sectors to generate electricity, produce chemical fuels, and drive energy-intensive processing of materials. The easy thermal design of the solar receiver is essential for the deployment of this renewable energy. This work proposes the equations and methodology to solve the steady-state energy balance of directly irradiated bubbling fluidized beds. The analysis focuses on solving the heating of the bed surface assuming that the energy flux received at the bed surface is absorbed through a layer of particles. The proposed methodology considers a volumetric energy balance of the top-bed surface to calculate the bed temperature. The bed surface emissivity ( ε b ) is a critical parameter in order to solve such an energy balance. To deal with the radiative losses, a correlation is proposed to estimate bed emissivity at the top-bed surface that depends on the dimensionless length number, d p * = A r 1 3 . The results are validated against both new experimental and literature data for the open and closed fluidized bed receivers. The absolute relative error when estimating the steady state temperature of the systems studied is about 5.2 % (on average). The relative error follows a Gaussian distribution guaranteeing an unbiased estimation of the bed temperatures at steady-state operation.

International Journal of Heat and Mass TransferVol. 236
Hospital General Universitario de Albacete (ES), Universidad Carlos III de Madrid (ES), University of Castilla-La Mancha (ES)
Ministerio de Ciencia, Innovación y Universidades, Ministerio de Ciencia e Innovación, Universidad de Castilla-La Mancha, Junta de Comunidades de Castilla-La Mancha, European Regional Development Fund, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 16%
Cyclone Separators and Fluid Dynamics
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.