Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive

Operating overvoltage occurs when the pantograph or main breaker of an electric locomotive is operated, which is prone to causing insulation failure of high-voltage equipment. The HXD1 electric locomotive is taken as the research object in this paper to explore the characteristics and influencing factors of operating overvoltage. Under pantograph lifting, main breaker closing, main breaker opening, and pantograph dropping, operating overvoltage waveform in the high-voltage system is recorded by a high-speed oscilloscope and resistance–capacitance voltage divider to analyze the overvoltage characteristics and distribution law. Tested data show that the amplitude of operating overvoltage is in the range of 80 to 330 kV with ultra-high steepness, which is similar to the Very Fast Transient Overvoltage (VFTO) in power systems. The maximum overvoltage during the entire test occurred during the main breaker closing and its amplitude is 328.60 kV with a steepness of 4.21 × 104 kV/μs. The max overvoltage of the other operations (pantograph lifting, main breaker opening, and pantograph dropping) are 280.60 kV, 194.73 kV, and 305.56 kV with ultra-high steepness. High-amplitude overvoltage is predominantly located at the pantograph, while the low-amplitude sort is mainly observed around other high-voltage equipment. The result indicates that operating overvoltage belongs to ultra-fast transient overvoltage and its amplitude and steepness are higher than existing research.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-10-19
DOI
https://doi.org/10.3390/app14209561
Citations
4
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive

Fuqiang Tian, Hongqi Liu, Yufeng Yin, Yike Guo
4 citations
Applied Sciences
Power Systems and Technologies
0.83
article

Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive

Fuqiang Tian, Hongqi Liu, Yufeng Yin, Yike Guo
article en
4 citations

Abstract

Operating overvoltage occurs when the pantograph or main breaker of an electric locomotive is operated, which is prone to causing insulation failure of high-voltage equipment. The HXD1 electric locomotive is taken as the research object in this paper to explore the characteristics and influencing factors of operating overvoltage. Under pantograph lifting, main breaker closing, main breaker opening, and pantograph dropping, operating overvoltage waveform in the high-voltage system is recorded by a high-speed oscilloscope and resistance–capacitance voltage divider to analyze the overvoltage characteristics and distribution law. Tested data show that the amplitude of operating overvoltage is in the range of 80 to 330 kV with ultra-high steepness, which is similar to the Very Fast Transient Overvoltage (VFTO) in power systems. The maximum overvoltage during the entire test occurred during the main breaker closing and its amplitude is 328.60 kV with a steepness of 4.21 × 104 kV/μs. The max overvoltage of the other operations (pantograph lifting, main breaker opening, and pantograph dropping) are 280.60 kV, 194.73 kV, and 305.56 kV with ultra-high steepness. High-amplitude overvoltage is predominantly located at the pantograph, while the low-amplitude sort is mainly observed around other high-voltage equipment. The result indicates that operating overvoltage belongs to ultra-fast transient overvoltage and its amplitude and steepness are higher than existing research.

Applied SciencesVol. 14(20)
Beijing Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 26%
Power Systems and Technologies
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.