Improved Biocompatibility in Laser-Polished Implants

This research aims to enhance the surface quality, mechanical properties, and biocompatibility of PEEK (polyether-ether-ketone) biomimetic dental implants through laser polishing. The objective is to improve osseointegration and implant durability by reducing surface roughness, increasing hydrophilicity, and enhancing mechanical strength. The methodology involved fabricating PEEK implants via FDM and applying laser polishing. The significant findings showed a 66.7% reduction in surface roughness, Ra reduced from 2.4 µm to 0.8 µm, and a 25.3% improvement in hydrophilicity, water contact angle decreased from 87° to 65°. Mechanical tests revealed a 6.3% increase in tensile strength (96 MPa to 102 MPa) and a 50% improvement in fatigue resistance (100,000 to 150,000 cycles). The strength analysis result showed a 10% increase in stiffness storage modulus from 1400 MPa to 1500 MPa. Error analysis showed a standard deviation of ±3% across all tests. In conclusion, laser polishing significantly improves the surface, mechanical, and biological performance of PEEK implants, making it a promising approach for advancing biomimetic dental implant technology.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2024-10-18
DOI
https://doi.org/10.3390/biomimetics9100642
Citations
5
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Biocompatibility in Laser-Polished Implants

Francis T. Omigbodun, Bankole I. Oladapo, Mattew A. Olawumi
5 citations
Biomimetics
Bone Tissue Engineering Materials
0.92
article

Improved Biocompatibility in Laser-Polished Implants

Francis T. Omigbodun, Bankole I. Oladapo, Mattew A. Olawumi
article en
5 citations

Abstract

This research aims to enhance the surface quality, mechanical properties, and biocompatibility of PEEK (polyether-ether-ketone) biomimetic dental implants through laser polishing. The objective is to improve osseointegration and implant durability by reducing surface roughness, increasing hydrophilicity, and enhancing mechanical strength. The methodology involved fabricating PEEK implants via FDM and applying laser polishing. The significant findings showed a 66.7% reduction in surface roughness, Ra reduced from 2.4 µm to 0.8 µm, and a 25.3% improvement in hydrophilicity, water contact angle decreased from 87° to 65°. Mechanical tests revealed a 6.3% increase in tensile strength (96 MPa to 102 MPa) and a 50% improvement in fatigue resistance (100,000 to 150,000 cycles). The strength analysis result showed a 10% increase in stiffness storage modulus from 1400 MPa to 1500 MPa. Error analysis showed a standard deviation of ±3% across all tests. In conclusion, laser polishing significantly improves the surface, mechanical, and biological performance of PEEK implants, making it a promising approach for advancing biomimetic dental implant technology.

BiomimeticsVol. 9(10)
Loughborough University (GB), University of Dundee (GB), De Montfort University (GB)
University of Dundee
Clean water and sanitation
Openalex Percentile: Top 28%
Bone Tissue Engineering Materials
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.