Access to an ELM-suppressed X-point radiator regime in TCV snowflake minus configurations

TCV’s operating regime with an X-point radiator (XPR) has been broadened by changing the magnetic geometry. XPRs have properties that could make them an attractive power exhaust solution for fusion reactors. These include the conversion of a high fraction of exhaust power into radiation. TCV had previously accessed the XPR regime only with difficulties, as predicted for plasmas where radiative losses are dominated by carbon impurities, that are ubiquitous in TCV. Guided by this theoretical model of the XPR, recent experiments employed TCV’s configurational versatility to demonstrate that XPR access can be facilitated by introducing a second X-point in the vicinity of the separatrix. This configuration, which has a snowflake-minus topology, features a particularly long magnetic connection length from the region just above the X-point to the outer midplane together with a wide geometrical interface with the private flux region that reaches high neutral pressure. Transitioning to this configuration in a high-power H-mode leads to a shift in the radiating region across the separatrix from the divertor to a volume above the X-point, i.e. within the last closed flux surface (LCFS). This displacement of the radiating region is co-incident with the disappearance of edge localised modes (ELMs), while retaining H-mode confinement, a behaviour only, to date, observed in devices with metallic walls. In contrast to observations in these other devices, on TCV, the primary strike points in these configurations remain attached. Detailed measurements of the plasma kinetic parameters inside and outside of the separatrix now challenge the models for access and stability of the XPR and ELMs alike.

Authors

Publication Details

Journal
Nuclear Materials and Energy
Published
2024-10-20
DOI
https://doi.org/10.1016/j.nme.2024.101784
Citations
4
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
2.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Access to an ELM-suppressed X-point radiator regime in TCV snowflake minus configurations

K. Lee, B.P. Duval, L. Simons, A. Thornton et al.
4 citations
Nuclear Materials and Energy
Magnetic confinement fusion research
2.64
article

Access to an ELM-suppressed X-point radiator regime in TCV snowflake minus configurations

K. Lee, B.P. Duval, L. Simons, A. Thornton, Daniel Hamm, Y.S. Wang, H. Reimerdes, C. Theiler, C. Wüthrich, M. Bernert, O. Pan, Guangyu Sun, S. Gorno, A. Perek, M. Zurita, O. Février, K. Verhaegh
article en
4 citations

Abstract

TCV’s operating regime with an X-point radiator (XPR) has been broadened by changing the magnetic geometry. XPRs have properties that could make them an attractive power exhaust solution for fusion reactors. These include the conversion of a high fraction of exhaust power into radiation. TCV had previously accessed the XPR regime only with difficulties, as predicted for plasmas where radiative losses are dominated by carbon impurities, that are ubiquitous in TCV. Guided by this theoretical model of the XPR, recent experiments employed TCV’s configurational versatility to demonstrate that XPR access can be facilitated by introducing a second X-point in the vicinity of the separatrix. This configuration, which has a snowflake-minus topology, features a particularly long magnetic connection length from the region just above the X-point to the outer midplane together with a wide geometrical interface with the private flux region that reaches high neutral pressure. Transitioning to this configuration in a high-power H-mode leads to a shift in the radiating region across the separatrix from the divertor to a volume above the X-point, i.e. within the last closed flux surface (LCFS). This displacement of the radiating region is co-incident with the disappearance of edge localised modes (ELMs), while retaining H-mode confinement, a behaviour only, to date, observed in devices with metallic walls. In contrast to observations in these other devices, on TCV, the primary strike points in these configurations remain attached. Detailed measurements of the plasma kinetic parameters inside and outside of the separatrix now challenge the models for access and stability of the XPR and ELMs alike.

Nuclear Materials and EnergyVol. 41
National Science Foundation, EUROfusion, European Commission, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Euratom Research and Training Programme, Staatssekretariat für Bildung, Forschung und Innovation
Climate action
Openalex Percentile: Top 7%
Magnetic confinement fusion research
2.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.