Quantifying Radiation Exposure in Minimally Invasive Spinal Surgery: A Single-Surgeon Study of Minimally Invasive Surgery-Oblique Lateral Lumbar Interbody Fusion (MIS-OLLIF) With Double C-Arm Technique

In the advancement of spinal surgery, minimally invasive techniques such as the oblique lateral lumbar interbody fusion (OLLIF) have emerged, offering improved clinical outcomes and the use of dual C-Arm intraoperative imaging. Despite the benefits, the radiation exposure to surgeons and staff from this dual-source imaging has not been thoroughly examined. This study aims to quantify the radiation exposure received by surgeons during OLLIF procedures, filling a gap in current research that primarily focuses on single-source imaging. Over 12 months, radiation doses were measured across 121 surgeries at four locations. Data analysis included average radiation exposure per surgery and variations across surgical sites. The findings showed an average radiation emission of 198.78 mGy per OLLIF surgery, with the surgeon receiving approximately 0.06 mSv per surgery. Cumulative doses for the surgeon were below the safety thresholds set by European and American standards. The significance of these findings lies in their contribution to the understanding of occupational safety in spinal surgery. The results indicate that with proper protective measures, such as lead aprons, the radiation exposure from the OLLIF technique is manageable within occupational limits. This study highlights the importance of monitoring radiation exposure and may influence the development of new guidelines and protective strategies in the field. Future research could expand the cohort of surgeons to validate these findings, develop new protective strategies, and explore radiation exposure in more complex multi-level fusions.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-20
DOI
https://doi.org/10.7759/cureus.71933
Citations
1
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying Radiation Exposure in Minimally Invasive Spinal Surgery: A Single-Surgeon Study of Minimally Invasive Surgery-Oblique Lateral Lumbar Interbody Fusion (MIS-OLLIF) With Double C-Arm Technique

Mitch A Rusten, Adam Šíma, D. F. Moore, Jiawen Zhan et al.
1 citations
Cureus
Spine and Intervertebral Disc Pathology
0.42
article

Quantifying Radiation Exposure in Minimally Invasive Spinal Surgery: A Single-Surgeon Study of Minimally Invasive Surgery-Oblique Lateral Lumbar Interbody Fusion (MIS-OLLIF) With Double C-Arm Technique

Mitch A Rusten, Adam Šíma, D. F. Moore, Jiawen Zhan, Twanesha Lightbourn, Hamidreza Abbasi
article en
1 citations

Abstract

In the advancement of spinal surgery, minimally invasive techniques such as the oblique lateral lumbar interbody fusion (OLLIF) have emerged, offering improved clinical outcomes and the use of dual C-Arm intraoperative imaging. Despite the benefits, the radiation exposure to surgeons and staff from this dual-source imaging has not been thoroughly examined. This study aims to quantify the radiation exposure received by surgeons during OLLIF procedures, filling a gap in current research that primarily focuses on single-source imaging. Over 12 months, radiation doses were measured across 121 surgeries at four locations. Data analysis included average radiation exposure per surgery and variations across surgical sites. The findings showed an average radiation emission of 198.78 mGy per OLLIF surgery, with the surgeon receiving approximately 0.06 mSv per surgery. Cumulative doses for the surgeon were below the safety thresholds set by European and American standards. The significance of these findings lies in their contribution to the understanding of occupational safety in spinal surgery. The results indicate that with proper protective measures, such as lead aprons, the radiation exposure from the OLLIF technique is manageable within occupational limits. This study highlights the importance of monitoring radiation exposure and may influence the development of new guidelines and protective strategies in the field. Future research could expand the cohort of surgeons to validate these findings, develop new protective strategies, and explore radiation exposure in more complex multi-level fusions.

CureusVol. 16(10)
Pain Clinic of India (IN), Inspired Spine (US)
Zero hunger
Openalex Percentile: Top 34%
Spine and Intervertebral Disc Pathology
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.