Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

Authors

Publication Details

Journal
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Published
2024-10-04
Primary Topic
Heat Transfer and Optimization
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of R290 variable geometry heat exchangers

B. O’Malley
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Heat Transfer and Optimization
article

Optimization of R290 variable geometry heat exchangers

B. O’Malley
article en

Abstract

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Affordable and clean energy
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.