Simulation analysis of different types of balloon dilatation catheters for the treatment of intracranial arterial stenosis

The application of balloon dilation catheters in the management of intracranial arterial stenosis has been gradually increasing. However, studies on the feasibility and effectiveness of different types of balloons remain relatively scarce. In this study, catheter models of three different materials were designed to simulate balloon crimping,splitting, and dilatation processes. A compliant balloon produces large deformations with poor dilatation and a stress concentration phenomenon. During dilatation, the shear stress generated in the intima and lesion area by the semi-compliant balloon was smaller than that generated by the non-compliant balloon. These results demonstrate the feasibility of using semi-compatible balloons.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2024-10-20
DOI
https://doi.org/10.1080/10255842.2024.2417207
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation analysis of different types of balloon dilatation catheters for the treatment of intracranial arterial stenosis

Yuan Yao, Jia‐Ping Huang, Haipo Cui
Computer Methods in Biomechanics & Biomedical Engineering
Cerebrovascular and Carotid Artery Diseases
article

Simulation analysis of different types of balloon dilatation catheters for the treatment of intracranial arterial stenosis

Yuan Yao, Jia‐Ping Huang, Haipo Cui
article en

Abstract

The application of balloon dilation catheters in the management of intracranial arterial stenosis has been gradually increasing. However, studies on the feasibility and effectiveness of different types of balloons remain relatively scarce. In this study, catheter models of three different materials were designed to simulate balloon crimping,splitting, and dilatation processes. A compliant balloon produces large deformations with poor dilatation and a stress concentration phenomenon. During dilatation, the shear stress generated in the intima and lesion area by the semi-compliant balloon was smaller than that generated by the non-compliant balloon. These results demonstrate the feasibility of using semi-compatible balloons.

Computer Methods in Biomechanics & Biomedical EngineeringVol. 29(4)
University of Shanghai for Science and Technology (CN), The Medical Device (United Kingdom) (GB)
Good health and well-being
Openalex Percentile: Top 66%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation analysis of different types of balloon dilatation catheters for the treatment of intracranial arterial stenosis — Yuan Yao, Jia‐Ping Huang, et al. · Computer Methods in Biomechanics & Biomedical Engineering (2024) | TGRS Research Map | TGRS