A computational analysis of similarity relations using helium as a surrogate of hydrogen in semi-confined facilities

Understanding hydrogen dispersion in a semi-confined space is crucial for the safe operation of hydrogen-related systems, such as hydrogen fuel cell vehicles. Analyzing hydrogen release and its subsequent dispersion can be effectively conducted using computational models, which necessitate experimental measurements for validation. For safety reasons, accidental scenarios are frequently replicated using helium as a hydrogen simulant in experiments, despite some concerns about the comparability of helium and hydrogen dispersions. Hence, this study conducts a comprehensive parametric numerical analysis of the similarities between hydrogen and helium dispersion when released in a semi-confined space. The model is based on the Macquarie Dispersion Chamber and the simulation results are first validated against the measurements. The study focuses on the impact of the leakage rate and ventilation velocity. Three release models were analysed: equal concentration (Method A), equal volumetric flow rate (Method B), and equal buoyancy (Method C). This study extends previous research on Method B, used for gas release in open spaces, to environments where flow-wall interactions become important. It also compares Methods A and C for a few scenarios, examining variations in concentration distribution, purge time, and activation time under different conditions. In the absence of ventilation, Method B effectively compares hydrogen and helium flow rates by accounting for volumetric flow rates, regardless of buoyancy effects. However, under increased ventilation velocities, Method A and Method C exhibit superior agreement across sensors, highlighting the necessity of choosing detection methods according to prevailing environmental conditions. • A CFD model for gas release in semi-confined space equipped with ventilation is established. • Three release models are studied to investigate similarity between hydrogen and helium gas dispersion. • Purge time and activation time are analysed with the aim of safe hydrogen infrastructure development. • Influence on gas dispersion by various ventilation velocity and flow rate at leakage are analysed.

Authors

Publication Details

Journal
International Journal of Hydrogen Energy
Published
2024-10-19
DOI
https://doi.org/10.1016/j.ijhydene.2024.10.071
Citations
7
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
9.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A computational analysis of similarity relations using helium as a surrogate of hydrogen in semi-confined facilities

Parth Patel, Rouzbeh Abbassi, Til Baalisampang, Fatemeh Salehi et al.
7 citations
International Journal of Hydrogen Energy
Spacecraft and Cryogenic Technologies
9.09
article

A computational analysis of similarity relations using helium as a surrogate of hydrogen in semi-confined facilities

Parth Patel, Rouzbeh Abbassi, Til Baalisampang, Fatemeh Salehi, Vikram Garaniya, Ehsan Arzaghi
article en
7 citations

Abstract

Understanding hydrogen dispersion in a semi-confined space is crucial for the safe operation of hydrogen-related systems, such as hydrogen fuel cell vehicles. Analyzing hydrogen release and its subsequent dispersion can be effectively conducted using computational models, which necessitate experimental measurements for validation. For safety reasons, accidental scenarios are frequently replicated using helium as a hydrogen simulant in experiments, despite some concerns about the comparability of helium and hydrogen dispersions. Hence, this study conducts a comprehensive parametric numerical analysis of the similarities between hydrogen and helium dispersion when released in a semi-confined space. The model is based on the Macquarie Dispersion Chamber and the simulation results are first validated against the measurements. The study focuses on the impact of the leakage rate and ventilation velocity. Three release models were analysed: equal concentration (Method A), equal volumetric flow rate (Method B), and equal buoyancy (Method C). This study extends previous research on Method B, used for gas release in open spaces, to environments where flow-wall interactions become important. It also compares Methods A and C for a few scenarios, examining variations in concentration distribution, purge time, and activation time under different conditions. In the absence of ventilation, Method B effectively compares hydrogen and helium flow rates by accounting for volumetric flow rates, regardless of buoyancy effects. However, under increased ventilation velocities, Method A and Method C exhibit superior agreement across sensors, highlighting the necessity of choosing detection methods according to prevailing environmental conditions. • A CFD model for gas release in semi-confined space equipped with ventilation is established. • Three release models are studied to investigate similarity between hydrogen and helium gas dispersion. • Purge time and activation time are analysed with the aim of safe hydrogen infrastructure development. • Influence on gas dispersion by various ventilation velocity and flow rate at leakage are analysed.

International Journal of Hydrogen EnergyVol. 91
Openalex Percentile: Top 3%
Spacecraft and Cryogenic Technologies
9.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.