Validation of an UPLC-PDA Method for the Simultaneous Quantification of Phenol and Iomeprol in a Sterile Parenteral Preparation Used for Coeliac Plexus Block, and Its Application to a Pharmaceutical Stability Study

<b>Objectives:</b> A commonly applied analgesic therapy for patients with severe abdominal pain due to cancer-related pain in the upper abdomen, is coeliac plexus neurolysis (CPN). Herein, a combination product of phenol and an iodine contrast agent are injected simultaneously. The chemical stability of such a combination product is unknown, and no chromatographic method is yet available that describes the simultaneous quantification of phenol and iomeprol. The aim of this study was to develop and validate a stability-indicating UPLC method for the simultaneous quantification of both phenol and iomeprol and to determine the chemical stability of a sterile 100 mg/mL phenol in 350 mg I/mL iomeprol solution for injection during shelf life. <b>Methods:</b> The product was compounded and sterilized in a GMP certified facility. The pharmaceutical analysis was validated by determination of the accuracy, precision, specificity, selectivity, carry-over and linearity. Pharmaceutical product stability was determined before and after sterilization, and during shelf life of 36 months at 25°C ± 2°C. <b>Results:</b> The accuracy for phenol and iomeprol was 97.1% to 99.3% and 100.0% to 100.2%, respectively. The RSD for repeatability and reproducibility for phenol were 0.65% and 1.17%, and for iomeprol 0.61% and 1.49%, respectively. All other tested parameters met the predefined validation criteria. All concentrations at all tested time points remained within ±2% of the initial concentrations for phenol and ±4% for iomeprol. No additional peaks were visible on the chromatograms. <b>Conclusion:</b> A stability-indicating method for the simultaneous quantification of phenol and iomeprol in a parental pharmaceutical preparation was developed and validated. This method was used to demonstrate the chemical stability of a newly developed sterile solution of 100 mg/mL phenol and 350 mg I/mL iomeprol. Chemical product stability was demonstrated during shelf life of up to 36 months.

Authors

Institutions

Publication Details

Journal
Hospital Pharmacy
Published
2024-10-18
DOI
https://doi.org/10.1177/00185787241289023
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an UPLC-PDA Method for the Simultaneous Quantification of Phenol and Iomeprol in a Sterile Parenteral Preparation Used for Coeliac Plexus Block, and Its Application to a Pharmaceutical Stability Study

Hans A. van Suijlekom, A. A. L. Rutgers, Mieke W. de Blois, Sjoerd D. Meenks et al.
Hospital Pharmacy
Analytical Methods in Pharmaceuticals
article

Validation of an UPLC-PDA Method for the Simultaneous Quantification of Phenol and Iomeprol in a Sterile Parenteral Preparation Used for Coeliac Plexus Block, and Its Application to a Pharmaceutical Stability Study

Hans A. van Suijlekom, A. A. L. Rutgers, Mieke W. de Blois, Sjoerd D. Meenks, R.A.C. van Wezel, Willemijn J. Jansen, Maarten J. Deenen, Anne A. Drost-Wijnne
article en

Abstract

<b>Objectives:</b> A commonly applied analgesic therapy for patients with severe abdominal pain due to cancer-related pain in the upper abdomen, is coeliac plexus neurolysis (CPN). Herein, a combination product of phenol and an iodine contrast agent are injected simultaneously. The chemical stability of such a combination product is unknown, and no chromatographic method is yet available that describes the simultaneous quantification of phenol and iomeprol. The aim of this study was to develop and validate a stability-indicating UPLC method for the simultaneous quantification of both phenol and iomeprol and to determine the chemical stability of a sterile 100 mg/mL phenol in 350 mg I/mL iomeprol solution for injection during shelf life. <b>Methods:</b> The product was compounded and sterilized in a GMP certified facility. The pharmaceutical analysis was validated by determination of the accuracy, precision, specificity, selectivity, carry-over and linearity. Pharmaceutical product stability was determined before and after sterilization, and during shelf life of 36 months at 25°C ± 2°C. <b>Results:</b> The accuracy for phenol and iomeprol was 97.1% to 99.3% and 100.0% to 100.2%, respectively. The RSD for repeatability and reproducibility for phenol were 0.65% and 1.17%, and for iomeprol 0.61% and 1.49%, respectively. All other tested parameters met the predefined validation criteria. All concentrations at all tested time points remained within ±2% of the initial concentrations for phenol and ±4% for iomeprol. No additional peaks were visible on the chromatograms. <b>Conclusion:</b> A stability-indicating method for the simultaneous quantification of phenol and iomeprol in a parental pharmaceutical preparation was developed and validated. This method was used to demonstrate the chemical stability of a newly developed sterile solution of 100 mg/mL phenol and 350 mg I/mL iomeprol. Chemical product stability was demonstrated during shelf life of up to 36 months.

Hospital PharmacyVol. 60(2)
Radboud University Nijmegen (NL), Leiden University Medical Center (NL), Catharina Ziekenhuis (NL)
Openalex Percentile: Top 83%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.