Short‐circuit current of a hydropower plant with consideration of constant switching and fault arc voltages

Abstract The correct generator circuit breaker (GCB) dimensioning is essential for the safe and reliable operation of a power plant or generation system. The dimensioning is usually based on standardized calculation methods according to standards (IEC standard 60909‐0, IEC/IEEE standard 62271‐37‐013, IEEE Std C37), often supplemented by selected transient calculations. A non‐systematic approach can often be observed here, which does not adequately take into account significant influencing variables or operating states of the generator. This article therefore systematically examines various parameters that influence the short‐circuit current components of the generator and are relevant for the dimensioning of the generator circuit‐breaker: short‐circuit angle, operating point, impedance ratios, phase clearing, switching arc, and fault arc. The results of the current parameters most relevant to the dimensioning of the GCB were then compared for different calculation methods. Special attention was paid to the effect of the switching and fault arc, which were modelled as a constant arc voltage, and its effect on the short‐circuit currents is systematically recorded. This work aims to summarize all relevant variables that influence the generator short‐circuit current and are relevant for the dimensioning of the GCB and to present the different results based on a short‐circuit calculation according to the standard and transient calculation to create a basis for a proper dimensioning of the generator circuit breaker.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2024-10-17
DOI
https://doi.org/10.1049/gtd2.13297
Citations
1
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short‐circuit current of a hydropower plant with consideration of constant switching and fault arc voltages

Darko Brankovic, Robert Schuerhuber
1 citations
IET Generation Transmission & Distribution
Vacuum and Plasma Arcs
0.34
article

Short‐circuit current of a hydropower plant with consideration of constant switching and fault arc voltages

Darko Brankovic, Robert Schuerhuber
article en
1 citations

Abstract

Abstract The correct generator circuit breaker (GCB) dimensioning is essential for the safe and reliable operation of a power plant or generation system. The dimensioning is usually based on standardized calculation methods according to standards (IEC standard 60909‐0, IEC/IEEE standard 62271‐37‐013, IEEE Std C37), often supplemented by selected transient calculations. A non‐systematic approach can often be observed here, which does not adequately take into account significant influencing variables or operating states of the generator. This article therefore systematically examines various parameters that influence the short‐circuit current components of the generator and are relevant for the dimensioning of the generator circuit‐breaker: short‐circuit angle, operating point, impedance ratios, phase clearing, switching arc, and fault arc. The results of the current parameters most relevant to the dimensioning of the GCB were then compared for different calculation methods. Special attention was paid to the effect of the switching and fault arc, which were modelled as a constant arc voltage, and its effect on the short‐circuit currents is systematically recorded. This work aims to summarize all relevant variables that influence the generator short‐circuit current and are relevant for the dimensioning of the GCB and to present the different results based on a short‐circuit calculation according to the standard and transient calculation to create a basis for a proper dimensioning of the generator circuit breaker.

IET Generation Transmission & DistributionVol. 18(21)
Graz University of Technology (AT)
TU Graz, Internationale Beziehungen und Mobilitätsprogramme
Affordable and clean energy
Openalex Percentile: Top 39%
Vacuum and Plasma Arcs
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.