Energy retrofits: Factors affecting a just transition to better indoor air quality

In comparison with other European countries, Ireland has a disproportionately high number of poorly performing energy-inefficient buildings. Consequently, Ireland has one of the most ambitious energy retrofit programmes in Europe. The aim of this study was to evaluate the impact of deep energy renovation measures i.e. (replacement of heating system and upgrade to building envelope) on indoor air quality, thermal comfort and ventilation in a sample of primarily social housing in Ireland. A mixed methods approach including measurement of indoor air quality and a thermal comfort questionnaire survey was employed. Indoor concentration measurements of PM 2.5 , carbon dioxide, formaldehyde, and radon along with measurements of air temperature and relative humidity were made (N=14). Occupants (n=56) completed a thermal comfort questionnaire survey pre- and post-retrofit. Data collection ran from autumn 2020 until autumn 2023. Thermal comfort improved post-retrofit along with occupant satisfaction with the indoor thermal environment and heating-systems. Post-retrofit, higher bedroom CO 2 , and higher PM 2.5 concentrations were recorded in both living areas and bedrooms. Occupant behaviours e.g. blocking wall vents were significant predictors of poorer ventilation while smoking indoors was related to higher concentrations of PM 2.5 . In general, homes that had mechanical ventilation systems installed were better ventilated. Underventilation, as indicated by visible condensation or mould was observed in half of the social homes surveyed and reported by questionnaire respondents (26 %). Tailored communications to occupants regarding the important role of ventilation and indoor air quality is required as part of retrofit to optimise impacts on IEQ. • Indoor environments assessed in Irish social and private home energy retrofits. • Thermal comfort improved following retrofit • Higher PM 2.5 concentrations in social housing with smokers. • Higher concentrations of CO 2 in homes with blocked wall vents. • Occupant behaviour and ventilation type important predictors of indoor air quality.

Authors

Institutions

Publication Details

Journal
Indoor Environments
Published
2024-10-18
DOI
https://doi.org/10.1016/j.indenv.2024.100058
Citations
6
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy retrofits: Factors affecting a just transition to better indoor air quality

Victoria Hogan, Edel Doherty, Marie A. Coggins, Hilary Cowie et al.
6 citations
Indoor Environments
Building Energy and Comfort Optimization
1.59
article

Energy retrofits: Factors affecting a just transition to better indoor air quality

Victoria Hogan, Edel Doherty, Marie A. Coggins, Hilary Cowie, Nina Wemken, Asit Mishra, David J. Foster, Daniel Norton
article en
6 citations

Abstract

In comparison with other European countries, Ireland has a disproportionately high number of poorly performing energy-inefficient buildings. Consequently, Ireland has one of the most ambitious energy retrofit programmes in Europe. The aim of this study was to evaluate the impact of deep energy renovation measures i.e. (replacement of heating system and upgrade to building envelope) on indoor air quality, thermal comfort and ventilation in a sample of primarily social housing in Ireland. A mixed methods approach including measurement of indoor air quality and a thermal comfort questionnaire survey was employed. Indoor concentration measurements of PM 2.5 , carbon dioxide, formaldehyde, and radon along with measurements of air temperature and relative humidity were made (N=14). Occupants (n=56) completed a thermal comfort questionnaire survey pre- and post-retrofit. Data collection ran from autumn 2020 until autumn 2023. Thermal comfort improved post-retrofit along with occupant satisfaction with the indoor thermal environment and heating-systems. Post-retrofit, higher bedroom CO 2 , and higher PM 2.5 concentrations were recorded in both living areas and bedrooms. Occupant behaviours e.g. blocking wall vents were significant predictors of poorer ventilation while smoking indoors was related to higher concentrations of PM 2.5 . In general, homes that had mechanical ventilation systems installed were better ventilated. Underventilation, as indicated by visible condensation or mould was observed in half of the social homes surveyed and reported by questionnaire respondents (26 %). Tailored communications to occupants regarding the important role of ventilation and indoor air quality is required as part of retrofit to optimise impacts on IEQ. • Indoor environments assessed in Irish social and private home energy retrofits. • Thermal comfort improved following retrofit • Higher PM 2.5 concentrations in social housing with smokers. • Higher concentrations of CO 2 in homes with blocked wall vents. • Occupant behaviour and ventilation type important predictors of indoor air quality.

Indoor EnvironmentsVol. 1(4)
Ollscoil na Gaillimhe – University of Galway (IE), University College Cork (IE), Institute of Occupational Medicine (GB), Technical University of Denmark (DK)
Affordable and clean energy
Openalex Percentile: Top 18%
Building Energy and Comfort Optimization
1.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.