Enhancing Gait Recognition in Lower Limb Exoskeletons: Adaptive Feature Selection and Random Forest With Bayesian Optimization

Abstract To improve human–machine cooperation and enhance the accuracy of gait recognition in wearable lower limb exoskeletons, an enhancement method of gait recognition based on adaptive feature selection and an optimized machine learning algorithm was proposed. In this study, surface electromyography (sEMG) signals of rectus femoris, medialis femoris, lateralis femoris, semitendinosus, and biceps femoris were recorded during level-ground walking. Then, time-domain (TD), frequency domain (FD), time-frequency domain (T-FD), and nonlinear features were extracted. The integrated values of electromyography, variance, root-mean-square, and wavelength were selected as the time-domain features, and the mean power frequency and median frequency were selected as the frequency domain features. Wavelet packet energy was selected as the time-frequency domain feature. Nonlinear features, including approximate entropy, sample entropy, and fuzzy entropy of sEMG were extracted. To reduce feature dimension and improve the calculation efficiency, adaptive feature selection was performed by particle swarm optimization combined with sigmoid function. Then, the feature matrix was determined as the input for a random forest classifier to recognize different gait phases. An adaptive optimization mechanism based on Bayesian optimization was applied to random forest. Compared with random forest, the overall performance of the optimized model was improved. Its accuracy was increased by 3.57%. The feature selection and adaptive optimization mechanisms in gait recognition not only enhance the accuracy of random forest algorithms applied to sEMG for gait prediction but also facilitate the flexibility and consistency required for lower limb exoskeleton gait control.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2024-10-18
DOI
https://doi.org/10.1115/1.4066923
Citations
1
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Gait Recognition in Lower Limb Exoskeletons: Adaptive Feature Selection and Random Forest With Bayesian Optimization

Haonan Geng, Xudong Guo, Fengqi Zhong, Haipo Cui et al.
1 citations
Journal of Medical Devices
Medical Imaging and Analysis
0.18
article

Enhancing Gait Recognition in Lower Limb Exoskeletons: Adaptive Feature Selection and Random Forest With Bayesian Optimization

Haonan Geng, Xudong Guo, Fengqi Zhong, Haipo Cui, Zhan Zhao, Haibo Lin, Guojie Zhang
article en
1 citations

Abstract

Abstract To improve human–machine cooperation and enhance the accuracy of gait recognition in wearable lower limb exoskeletons, an enhancement method of gait recognition based on adaptive feature selection and an optimized machine learning algorithm was proposed. In this study, surface electromyography (sEMG) signals of rectus femoris, medialis femoris, lateralis femoris, semitendinosus, and biceps femoris were recorded during level-ground walking. Then, time-domain (TD), frequency domain (FD), time-frequency domain (T-FD), and nonlinear features were extracted. The integrated values of electromyography, variance, root-mean-square, and wavelength were selected as the time-domain features, and the mean power frequency and median frequency were selected as the frequency domain features. Wavelet packet energy was selected as the time-frequency domain feature. Nonlinear features, including approximate entropy, sample entropy, and fuzzy entropy of sEMG were extracted. To reduce feature dimension and improve the calculation efficiency, adaptive feature selection was performed by particle swarm optimization combined with sigmoid function. Then, the feature matrix was determined as the input for a random forest classifier to recognize different gait phases. An adaptive optimization mechanism based on Bayesian optimization was applied to random forest. Compared with random forest, the overall performance of the optimized model was improved. Its accuracy was increased by 3.57%. The feature selection and adaptive optimization mechanisms in gait recognition not only enhance the accuracy of random forest algorithms applied to sEMG for gait prediction but also facilitate the flexibility and consistency required for lower limb exoskeleton gait control.

Journal of Medical DevicesVol. 19(1)
University of Shanghai for Science and Technology (CN), Taiyuan Iron and Steel Group (China) (CN)
Openalex Percentile: Top 52%
Medical Imaging and Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.