Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition

The far-UVC (222 nm) system has emerged as a solution for controlling airborne transmission, yet its effect on indoor air quality, particularly concerning positioning, remains understudied. In this study, we examined the impact of far-UVC lamp position on the disinfection and secondary contaminant formation in a small office. We employed a three-dimensional computational fluid dynamics (CFD) model to integrate UV intensity fields formed by different lamp positions (ceiling-mounted, wall-mounted, and stand-alone types) along with the air quality model. Our findings reveal that the ceiling-mounted type reduces human exposure to airborne pathogens by up to 80% compared to scenarios without far-UVC. For all the lamp positions, O<sub>3</sub> concentration in the breathing zone increases by 4-6 ppb after one hour of operation. However, it should be noted that a high concentration zone (> 25 ppb) forms near the lamp when it is turned on. Moreover, ventilation plays a crucial role in determining human exposure to airborne pathogens and secondary contaminants. Increasing the ventilation rate from 0.7 h<sup>-1</sup> to 4 h<sup>-1</sup> reduces airborne pathogen and secondary contaminant concentrations by up to 90%. However, caution is warranted as higher ventilation rates can lead to elevated O<sub>3</sub> indoors, especially under conditions of high outdoor O<sub>3</sub> concentrations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-18
DOI
https://doi.org/10.1038/s41598-024-75245-z
Citations
6
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
2.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition

Donghyun Rim, Seongjun Park
6 citations
Scientific Reports
Infection Control and Ventilation
2.51
article

Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition

Donghyun Rim, Seongjun Park
article en
6 citations

Abstract

The far-UVC (222 nm) system has emerged as a solution for controlling airborne transmission, yet its effect on indoor air quality, particularly concerning positioning, remains understudied. In this study, we examined the impact of far-UVC lamp position on the disinfection and secondary contaminant formation in a small office. We employed a three-dimensional computational fluid dynamics (CFD) model to integrate UV intensity fields formed by different lamp positions (ceiling-mounted, wall-mounted, and stand-alone types) along with the air quality model. Our findings reveal that the ceiling-mounted type reduces human exposure to airborne pathogens by up to 80% compared to scenarios without far-UVC. For all the lamp positions, O<sub>3</sub> concentration in the breathing zone increases by 4-6 ppb after one hour of operation. However, it should be noted that a high concentration zone (> 25 ppb) forms near the lamp when it is turned on. Moreover, ventilation plays a crucial role in determining human exposure to airborne pathogens and secondary contaminants. Increasing the ventilation rate from 0.7 h<sup>-1</sup> to 4 h<sup>-1</sup> reduces airborne pathogen and secondary contaminant concentrations by up to 90%. However, caution is warranted as higher ventilation rates can lead to elevated O<sub>3</sub> indoors, especially under conditions of high outdoor O<sub>3</sub> concentrations.

Scientific ReportsVol. 14(1)
Pennsylvania State University (US), Harvard University (US)
National Science Foundation, Division of Chemical, Bioengineering, Environmental, and Transport Systems
Openalex Percentile: Top 10%
Infection Control and Ventilation
2.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition — Donghyun Rim, Seongjun Park · Scientific Reports (2024) | TGRS Research Map | TGRS