Seismic isolation design of high-rise shear wall structures in high-intensity areas

Taking a shear wall structure in a high-intensity area of 20 floors as an example, the seismic reduction scheme of the structure was determined, and the Etabs software was used to conduct time history analysis on the seismic and non-seismic structures. The floor shear force, overturning moment, and short-term surface pressure of the isolation support were obtained. The results showed that under frequent earthquake action, the average maximum floor shear force in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> direction of the isolated upper structure was only about 28 % of that of the non-isolated structure. The maximum inter story shear ratio was 0.34, and the maximum floor shear force in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> direction was only about 25 % of that of the non-isolated structure. The maximum inter story shear ratio was 0.31. The average maximum overturning moment of the upper structure in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> direction after isolation is about 30 % of that of the non-isolated structure. The maximum overturning moment ratio is 0.36, and the average overturning moment of the maximum floor in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> direction is about 22 % of that of the non-isolated structure. The maximum overturning moment ratio is 0.26. Under rare earthquake action, the maximum inter story displacement angles in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> directions of each floor of the seismic isolation structure are 1/302 and 1/446, respectively. The maximum surface pressure value of the isolation bearing under rare earthquake is 28.9 MPa, the minimum surface pressure value is 5.58 MPa, and the maximum displacement is 579 mm, which meets the requirements of the specifications. Overall, the seismic performance of the seismic isolation structure is good, and the isolation scheme is feasible.

Authors

Publication Details

Journal
Vibroengineering PROCEDIA
Published
2024-10-18
DOI
https://doi.org/10.21595/vp.2024.24414
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic isolation design of high-rise shear wall structures in high-intensity areas

Shuting Du, Shufeng Li, Zhihui Zhang, Weijie Zhu
Vibroengineering PROCEDIA
Seismic Performance and Analysis
article

Seismic isolation design of high-rise shear wall structures in high-intensity areas

Shuting Du, Shufeng Li, Zhihui Zhang, Weijie Zhu
article en

Abstract

Taking a shear wall structure in a high-intensity area of 20 floors as an example, the seismic reduction scheme of the structure was determined, and the Etabs software was used to conduct time history analysis on the seismic and non-seismic structures. The floor shear force, overturning moment, and short-term surface pressure of the isolation support were obtained. The results showed that under frequent earthquake action, the average maximum floor shear force in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> direction of the isolated upper structure was only about 28 % of that of the non-isolated structure. The maximum inter story shear ratio was 0.34, and the maximum floor shear force in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> direction was only about 25 % of that of the non-isolated structure. The maximum inter story shear ratio was 0.31. The average maximum overturning moment of the upper structure in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> direction after isolation is about 30 % of that of the non-isolated structure. The maximum overturning moment ratio is 0.36, and the average overturning moment of the maximum floor in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> direction is about 22 % of that of the non-isolated structure. The maximum overturning moment ratio is 0.26. Under rare earthquake action, the maximum inter story displacement angles in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>X</mml:mi></mml:math> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>Y</mml:mi></mml:math> directions of each floor of the seismic isolation structure are 1/302 and 1/446, respectively. The maximum surface pressure value of the isolation bearing under rare earthquake is 28.9 MPa, the minimum surface pressure value is 5.58 MPa, and the maximum displacement is 579 mm, which meets the requirements of the specifications. Overall, the seismic performance of the seismic isolation structure is good, and the isolation scheme is feasible.

Vibroengineering PROCEDIAVol. 56
Sustainable cities and communities
Openalex Percentile: Top 79%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.