Detecting bubbles via FDR and FNR based on calibrated <i>p</i> -values

Detecting bubbles in asset prices is still an open question that has attracted considerable attention in recent years. This paper improves the bubble detection and dating approaches developed in recent years by Phillips and co-authors, proposing to assess the plausibility of its outcomes via the false discovery rate (FDR) and the false non-discovery rate (FNR) based on calibrated p-values. Calibrating p-values of unit root tests, applied sequentially to detect bubbles, allows recovery of their super-uniformity property, which is crucial for a valid implementation of the inferential procedure. The paper also develops original self-calibrated versions of both FDR and FNR for the specific problem of bubble testing. Calibrated p-values are implemented in an online false discovery-based approach which monitors bubbles in real time. The effectiveness of the proposed methods is investigated via a simulation study and an empirical application.

Authors

Institutions

Publication Details

Journal
Quantitative Finance
Published
2024-10-02
DOI
https://doi.org/10.1080/14697688.2024.2406561
Citations
1
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting bubbles via FDR and FNR based on calibrated p -values

Piero Quatto, Gianmarco Vacca, Giulia Genoni
1 citations
Quantitative Finance
Medical Image Segmentation Techniques
0.25
article

Detecting bubbles via FDR and FNR based on calibrated p -values

Piero Quatto, Gianmarco Vacca, Giulia Genoni
article en
1 citations

Abstract

Detecting bubbles in asset prices is still an open question that has attracted considerable attention in recent years. This paper improves the bubble detection and dating approaches developed in recent years by Phillips and co-authors, proposing to assess the plausibility of its outcomes via the false discovery rate (FDR) and the false non-discovery rate (FNR) based on calibrated p-values. Calibrating p-values of unit root tests, applied sequentially to detect bubbles, allows recovery of their super-uniformity property, which is crucial for a valid implementation of the inferential procedure. The paper also develops original self-calibrated versions of both FDR and FNR for the specific problem of bubble testing. Calibrated p-values are implemented in an online false discovery-based approach which monitors bubbles in real time. The effectiveness of the proposed methods is investigated via a simulation study and an empirical application.

Quantitative FinanceVol. 24(10)
Università Cattolica del Sacro Cuore (IT), Università della Svizzera italiana (CH), University of Milano-Bicocca (IT)
Openalex Percentile: Top 46%
Medical Image Segmentation Techniques
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.