The Impact of Homogenization Techniques and Conditions on Water‐In‐Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study

This study aims to evaluate homogenization techniques and conditions for producing stable, small droplet-size water-in-oil (W/O) emulsions intended for incorporation into casein hydrolysate-loaded double emulsions. Three commonly used homogenization methods; rotor-stator, ultrasonic, and high-pressure homogenization were individually optimized utilizing response surface methodology. Instances of over-processing were observed, particularly with the rotor-stator and ultrasonic homogenizers under specific conditions. Nevertheless, optimal conditions were identified for each technique: 530 s at 17,800 rpm agitation speed for the rotor-stator homogenizer, 139 s at 39% amplitude for the ultrasonic homogenizer, and 520 s at 1475 bar for the high-pressure homogenizer. Subsequently, the W/O emulsions produced under optimal conditions and their respective W<sub>1</sub>/O/W<sub>2</sub> double emulsions were compared. The rotor-stator and high-pressure homogenized W/O emulsions exhibited comparable narrow droplet-size distributions, as indicated by similar Span values. However, high-pressure homogenization failed to sufficiently minimize droplet size. Ultrasonic homogenization resulted in droplets at the 1-μm scale but yielded more polydisperse droplet-size distribution. According to TOPSIS analysis, an emulsion with a viscosity of 93.1 cP (centiPoise), a stability index of 93.8%, a D(90) of 0.67 μm (0th day), and a D(90) of 0.75 μm (30th day) produced using a rotor-stator was selected. Additionally, double emulsions containing primary emulsions prepared with the rotor-stator method demonstrated higher viscosity, narrower droplet-size distribution, and lower creaming compared to other samples. This investigation sheds light on the influence of homogenization techniques on emulsion properties, providing valuable insights for optimizing double emulsion formulations.

Authors

Institutions

Publication Details

Journal
Food Science & Nutrition
Published
2024-10-18
DOI
https://doi.org/10.1002/fsn3.4525
Citations
6
Primary Topic
Proteins in Food Systems
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Homogenization Techniques and Conditions on Water‐In‐Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study

Onur Güven, Mustafa Çam, Çağla Ulubaş, Pelin Salum et al.
6 citations
Food Science & Nutrition
Proteins in Food Systems
2.09
article

The Impact of Homogenization Techniques and Conditions on Water‐In‐Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study

Onur Güven, Mustafa Çam, Çağla Ulubaş, Pelin Salum, Zafer Erbay, Levent Yurdaer Aydemir
article en
6 citations

Abstract

This study aims to evaluate homogenization techniques and conditions for producing stable, small droplet-size water-in-oil (W/O) emulsions intended for incorporation into casein hydrolysate-loaded double emulsions. Three commonly used homogenization methods; rotor-stator, ultrasonic, and high-pressure homogenization were individually optimized utilizing response surface methodology. Instances of over-processing were observed, particularly with the rotor-stator and ultrasonic homogenizers under specific conditions. Nevertheless, optimal conditions were identified for each technique: 530 s at 17,800 rpm agitation speed for the rotor-stator homogenizer, 139 s at 39% amplitude for the ultrasonic homogenizer, and 520 s at 1475 bar for the high-pressure homogenizer. Subsequently, the W/O emulsions produced under optimal conditions and their respective W<sub>1</sub>/O/W<sub>2</sub> double emulsions were compared. The rotor-stator and high-pressure homogenized W/O emulsions exhibited comparable narrow droplet-size distributions, as indicated by similar Span values. However, high-pressure homogenization failed to sufficiently minimize droplet size. Ultrasonic homogenization resulted in droplets at the 1-μm scale but yielded more polydisperse droplet-size distribution. According to TOPSIS analysis, an emulsion with a viscosity of 93.1 cP (centiPoise), a stability index of 93.8%, a D(90) of 0.67 μm (0th day), and a D(90) of 0.75 μm (30th day) produced using a rotor-stator was selected. Additionally, double emulsions containing primary emulsions prepared with the rotor-stator method demonstrated higher viscosity, narrower droplet-size distribution, and lower creaming compared to other samples. This investigation sheds light on the influence of homogenization techniques on emulsion properties, providing valuable insights for optimizing double emulsion formulations.

Food Science & NutritionVol. 12(11)
Adana Science and Technology University (TR), Erciyes University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Clean water and sanitation
Openalex Percentile: Top 14%
Proteins in Food Systems
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.