Tailoring Ruthenium(II) and Rhenium(I) Complexes for Turn-On Luminescent Sensing of Antimony(III)

Antimony (Sb) is currently a widespread element with key roles in telecommunication, sustainable energy, and military industries, among others. Its significant toxicity determines the need to realize sensors for water, air, and soil and the industrial process monitoring of Sb species. Unfortunately, no antimony sensors exist so far, and just laboratory analysis methods are in use. We aimed to contribute to the development of optical sensors for the metalloid by tailoring, for the first time, luminescent Ru(II) and Re(I) polypyridyl complexes to probe and quantify the presence of Sb(III). The molecular design of the complexes includes the multifunctional Sb-binding 2-(2,2′-bithien-5-yl)-1H-imidazo[4,5-f]-1,10-phenanthroline (btip) ligand that ensures the molecular binding of Sb(III) in organic media. The Ru(II)-btip complex is additionally endowed with one 2,2′-bipyrazine (bpz) or two 1,4,5,8-tetraazaphenanthrene (tap) ligands, namely [Ru(bpz)(btip)2]2+ and [Ru(tap)2(btip)]2+, that boost the excited state oxidation potential of the probe, leading to an intramolecular photoinduced electron transfer from btip to the Ru(II) core. The latter is suppressed upon interaction with Sb(III), leading to an 11-fold increase in both the luminescence intensity and lifetime of [Ru(bpz)(btip)2]2+ in the presence of ca. 50 μmol L−1 of SbCl3 in organic medium. The fluorescence intensity of [Re(CO)3(H2O)(btip)]+ also increases upon interaction with Sb(III) but to a much lesser extent due to the intraligand π*→π nature of its emission compared to the Ru(II) ligand-to-metal excited state deactivation. However, the weak π*→d emission band in the red spectral region of the former is quenched by the semimetallic element. The sensing mechanisms of the Ru(II)- and Re(I)-btip probes that allow luminescence intensity (Ru, Re), ratiometric (Ru), and lifetime measurements (Ru) are compared and discussed in this initial solution sensing study.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2024-10-18
DOI
https://doi.org/10.3390/chemosensors12100217
Citations
3
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tailoring Ruthenium(II) and Rhenium(I) Complexes for Turn-On Luminescent Sensing of Antimony(III)

F. Ragone, Gustavo T. Ruiz, Guillermo Orellana, Alexandre Vieira Silva
3 citations
Chemosensors
Molecular Sensors and Ion Detection
0.72
article

Tailoring Ruthenium(II) and Rhenium(I) Complexes for Turn-On Luminescent Sensing of Antimony(III)

F. Ragone, Gustavo T. Ruiz, Guillermo Orellana, Alexandre Vieira Silva
article en
3 citations

Abstract

Antimony (Sb) is currently a widespread element with key roles in telecommunication, sustainable energy, and military industries, among others. Its significant toxicity determines the need to realize sensors for water, air, and soil and the industrial process monitoring of Sb species. Unfortunately, no antimony sensors exist so far, and just laboratory analysis methods are in use. We aimed to contribute to the development of optical sensors for the metalloid by tailoring, for the first time, luminescent Ru(II) and Re(I) polypyridyl complexes to probe and quantify the presence of Sb(III). The molecular design of the complexes includes the multifunctional Sb-binding 2-(2,2′-bithien-5-yl)-1H-imidazo[4,5-f]-1,10-phenanthroline (btip) ligand that ensures the molecular binding of Sb(III) in organic media. The Ru(II)-btip complex is additionally endowed with one 2,2′-bipyrazine (bpz) or two 1,4,5,8-tetraazaphenanthrene (tap) ligands, namely [Ru(bpz)(btip)2]2+ and [Ru(tap)2(btip)]2+, that boost the excited state oxidation potential of the probe, leading to an intramolecular photoinduced electron transfer from btip to the Ru(II) core. The latter is suppressed upon interaction with Sb(III), leading to an 11-fold increase in both the luminescence intensity and lifetime of [Ru(bpz)(btip)2]2+ in the presence of ca. 50 μmol L−1 of SbCl3 in organic medium. The fluorescence intensity of [Re(CO)3(H2O)(btip)]+ also increases upon interaction with Sb(III) but to a much lesser extent due to the intraligand π*→π nature of its emission compared to the Ru(II) ligand-to-metal excited state deactivation. However, the weak π*→d emission band in the red spectral region of the former is quenched by the semimetallic element. The sensing mechanisms of the Ru(II)- and Re(I)-btip probes that allow luminescence intensity (Ru, Re), ratiometric (Ru), and lifetime measurements (Ru) are compared and discussed in this initial solution sensing study.

ChemosensorsVol. 12(10)
Universidad Complutense de Madrid (ES), Consejo Nacional de Investigaciones Científicas y Técnicas (AR), Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (AR)
Ministerio de Ciencia e Innovación
Responsible consumption and production
Openalex Percentile: Top 33%
Molecular Sensors and Ion Detection
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.