The eGFR <sub>cystatin C</sub> /eGFR <sub>creatinine</sub> -ratio is associated with maternal morbidity in hypertensive disorders in pregnancy and may indicate optimal timing of delivery

A low eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio is characteristic of a group of serious kidney disorders called 'Selective Glomerular Hypofiltration Syndromes'. This study examines if such a low ratio can also be used to evaluate the risk for women with hypertensive disorders in pregnancy to develop severe maternal morbidity. All women discharged from the perinatal ward at the Skåne University Hospital in Lund during the period of 1-9-2016 to 31-8-2017 under one of the diagnoses within hypertensive disorders in pregnancy were considered for inclusion in the study. After delivery and discharge from the hospital, records from included patients were reviewed and all registered measures of renal function were analysed. An eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio ≤0.60 in a sample drawn not earlier than three days before delivery was considered as defining a high risk for severe maternal morbidity. A strong association (p-value: 0.035) between severe maternal morbidity and an eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio ≤0.60 was found in a subgroup of 32 women diagnosed with 'preeclampsia with severe features'. A total of 69 women were included in the study. Fifty were defined as high-risk and seventeen of them (34%) developed severe maternal morbidity. Among the nineteen women defined as low-risk only two (10.5%) developed severe maternal morbidity (p-value: 0.051). A low eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio seems promising as a predictive marker for maternal morbidity in hypertension in pregnancy. Its performance as a tool in the monitoring of progressing disease should be evaluated further in larger cohorts. Delivery before the eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio decreases to, or below, 0.60 might help avoid maternal complications.

Authors

Institutions

Publication Details

Journal
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2024-10-18
DOI
https://doi.org/10.1080/00365513.2024.2417379
Citations
2
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
1.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The eGFR cystatin C /eGFR creatinine -ratio is associated with maternal morbidity in hypertensive disorders in pregnancy and may indicate optimal timing of delivery

Anders Grubb, Danielle Damm, Helena Strevens
2 citations
Scandinavian Journal of Clinical and Laboratory Investigation
Pregnancy and preeclampsia studies
1.17
article

The eGFR cystatin C /eGFR creatinine -ratio is associated with maternal morbidity in hypertensive disorders in pregnancy and may indicate optimal timing of delivery

Anders Grubb, Danielle Damm, Helena Strevens
article en
2 citations

Abstract

A low eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio is characteristic of a group of serious kidney disorders called 'Selective Glomerular Hypofiltration Syndromes'. This study examines if such a low ratio can also be used to evaluate the risk for women with hypertensive disorders in pregnancy to develop severe maternal morbidity. All women discharged from the perinatal ward at the Skåne University Hospital in Lund during the period of 1-9-2016 to 31-8-2017 under one of the diagnoses within hypertensive disorders in pregnancy were considered for inclusion in the study. After delivery and discharge from the hospital, records from included patients were reviewed and all registered measures of renal function were analysed. An eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio ≤0.60 in a sample drawn not earlier than three days before delivery was considered as defining a high risk for severe maternal morbidity. A strong association (p-value: 0.035) between severe maternal morbidity and an eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio ≤0.60 was found in a subgroup of 32 women diagnosed with 'preeclampsia with severe features'. A total of 69 women were included in the study. Fifty were defined as high-risk and seventeen of them (34%) developed severe maternal morbidity. Among the nineteen women defined as low-risk only two (10.5%) developed severe maternal morbidity (p-value: 0.051). A low eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio seems promising as a predictive marker for maternal morbidity in hypertension in pregnancy. Its performance as a tool in the monitoring of progressing disease should be evaluated further in larger cohorts. Delivery before the eGFR<sub>cystatin C</sub>/eGFR<sub>creatinine</sub>-ratio decreases to, or below, 0.60 might help avoid maternal complications.

Scandinavian Journal of Clinical and Laboratory InvestigationVol. 84(7-8)
Lund University (SE), Skåne University Hospital (SE)
Zero hunger
Openalex Percentile: Top 19%
Pregnancy and preeclampsia studies
1.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.