Investigation of the cooling effect of wind on rooftop PV power plants

This study investigates the cooling of PV panels installed on the roof of a 5.9 MW power plant in Bursa, Turkey, under varying wind conditions. Meteorological measurements were conducted during the summer period to analyse the cooling effects. When wind speed differences were below 0.5 m/s, the cooling effect on the PV panels ranged between 2 and 3 °C. However, when the wind speed differences approached 1 m/s, the cooling effect increased up to 7 °C. At lower wind speeds, winds blowing from behind the panels provided better cooling, whereas side winds offered improved performance as wind speed increased. Due to the roof slope and the minimal gap between the panels and the roof, winds from behind were less effective, as they could not penetrate the back of the PV panels. Side winds, on the other hand, faced no difficulty in flowing over the panel surfaces but lost their cooling effect as they passed along the long rows of panels. These findings suggest that during the design phase of PV power plants, high wind speed locations should be prioritized, and optimal configurations should be implemented to ensure uniform wind access to all PV arrays.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-10-18
DOI
https://doi.org/10.1016/j.csite.2024.105295
Citations
16
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
1.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the cooling effect of wind on rooftop PV power plants

Nurullah Arslanoğlu, A. Ataman
16 citations
Case Studies in Thermal Engineering
Solar Thermal and Photovoltaic Systems
1.64
article

Investigation of the cooling effect of wind on rooftop PV power plants

Nurullah Arslanoğlu, A. Ataman
article en
16 citations

Abstract

This study investigates the cooling of PV panels installed on the roof of a 5.9 MW power plant in Bursa, Turkey, under varying wind conditions. Meteorological measurements were conducted during the summer period to analyse the cooling effects. When wind speed differences were below 0.5 m/s, the cooling effect on the PV panels ranged between 2 and 3 °C. However, when the wind speed differences approached 1 m/s, the cooling effect increased up to 7 °C. At lower wind speeds, winds blowing from behind the panels provided better cooling, whereas side winds offered improved performance as wind speed increased. Due to the roof slope and the minimal gap between the panels and the roof, winds from behind were less effective, as they could not penetrate the back of the PV panels. Side winds, on the other hand, faced no difficulty in flowing over the panel surfaces but lost their cooling effect as they passed along the long rows of panels. These findings suggest that during the design phase of PV power plants, high wind speed locations should be prioritized, and optimal configurations should be implemented to ensure uniform wind access to all PV arrays.

Case Studies in Thermal EngineeringVol. 63
Bursa Uludağ Üni̇versi̇tesi̇ (TR), Bursa Technical University (TR)
Affordable and clean energy
Openalex Percentile: Top 17%
Solar Thermal and Photovoltaic Systems
1.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.