Practical limits to spatial resolution of magnetic imaging with a quantum diamond microscope

Widefield quantum diamond microscopy is a powerful technique for imaging magnetic fields with high sensitivity and spatial resolution. However, current methods to approach the ultimate spatial resolution (<500 nm) are impractical for routine use as they require time-consuming fabrication or transfer techniques to precisely interface the diamond sensor with the sample to be imaged. To address this challenge, we have designed a co-axial sensor holder that enables simple, repeatable sensor–sample interfacing while being compatible with high numerical aperture (NA) optics. With our new design we demonstrate low standoffs <500 nm with a millimeter sized sensor. We also explore the relationship between spatial resolution and NA spanning from 0.13 to 1.3. The spatial resolution shows good agreement with the optical diffraction limit at low NA but deviates at high NA, which is shown to be due to optical aberrations. Future improvements to our design are discussed, which should enable magnetic imaging with <500 nm resolution in an accessible, easy-to-use instrument.

Authors

Institutions

Publication Details

Journal
AVS Quantum Science
Published
2024-10-18
DOI
https://doi.org/10.1116/5.0230098
Citations
9
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
1.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical limits to spatial resolution of magnetic imaging with a quantum diamond microscope

Sam C. Scholten, Islay O. Robertson, Priya Singh, David A. Broadway et al.
9 citations
AVS Quantum Science
Diamond and Carbon-based Materials Research
1.05
article

Practical limits to spatial resolution of magnetic imaging with a quantum diamond microscope

Sam C. Scholten, Islay O. Robertson, Priya Singh, David A. Broadway, Kevin J. Rietwyk, Alexander J. Healey, Jean‐Philippe Tetienne, Philipp Reineck, Alex Shaji
article en
9 citations

Abstract

Widefield quantum diamond microscopy is a powerful technique for imaging magnetic fields with high sensitivity and spatial resolution. However, current methods to approach the ultimate spatial resolution (<500 nm) are impractical for routine use as they require time-consuming fabrication or transfer techniques to precisely interface the diamond sensor with the sample to be imaged. To address this challenge, we have designed a co-axial sensor holder that enables simple, repeatable sensor–sample interfacing while being compatible with high numerical aperture (NA) optics. With our new design we demonstrate low standoffs <500 nm with a millimeter sized sensor. We also explore the relationship between spatial resolution and NA spanning from 0.13 to 1.3. The spatial resolution shows good agreement with the optical diffraction limit at low NA but deviates at high NA, which is shown to be due to optical aberrations. Future improvements to our design are discussed, which should enable magnetic imaging with <500 nm resolution in an accessible, easy-to-use instrument.

AVS Quantum ScienceVol. 6(4)
RMIT University (AU)
Australian Research Council
Openalex Percentile: Top 20%
Diamond and Carbon-based Materials Research
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.